Add like
Add dislike
Add to saved papers

Mobile Technology in Medicine: Development and Validation of an Adapted System Usability Scale (SUS) Questionnaire and Modified Technology Acceptance Model (TAM) to Evaluate User Experience and Acceptability of a Mobile Application in MRI Safety Screening.

Background  Magnetic resonance imaging (MRI) safety screening is a crucial procedure for patient preparation before entering into MRI room. Many hospitals in Malaysia are still using the MRI safety checklist printed form. Besides, clinicians will not get a definite conclusion about whether the patient is contraindicated for MRI or not. Hence, we have created one mobile application named MagnetoSafe to overcome this issue. The application will provide an instant decision on whether the patient has no contraindication, relative contraindication, or absolute contraindicated for MRI. We need to check for acceptability and user experience for any newly created mobile application. Objective  This study was designed to check the validity of the adapted Technology Acceptance Model (TAM) and System Usability Scale (SUS) Questionnaire. Method  The validity and reliability of the questionnaire were investigated. Subsequently, 52 fully completed responses were collected. Results  Face and content validity of the questionnaires are considered acceptable with only minor changes to Item 10 of SUS. The Cronbach's alpha for the SUS questionnaire (10 questions) is -0.49, which is not acceptable. The Cronbach's alpha for TAM questionnaire (3 domains; 14 questions) is acceptable, which is 0.910 for perceived usefulness, 0.843 for perceived ease of use, and 0.915 for intention to use. Conclusion  Face validity of the adapted SUS and modified TAM questionnaires is acceptable with only minor changes to Item 10 in SUS. Content validity with experts is good. However, the reliability of the SUS questionnaire is not acceptable and therefore adapted SUS will not be used for assessing user experience. The reliability of the modified TAM questionnaire with the original three-factor structure is considered acceptable and can be used to evaluate the user's acceptability of MagnetoSafe.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

Managing Alcohol Withdrawal Syndrome.Annals of Emergency Medicine 2024 March 26

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app