Add like
Add dislike
Add to saved papers

Diagnostic Effectiveness of Third-Trimester Fetal Doppler Studies in Pregnancy to Predict Late-and-Term Stillbirth and Neonatal Mortality in the Samrakshan Program in India.

Aim  To determine the diagnostic effectiveness of third-trimester fetal Doppler studies in pregnancy for stillbirths and neonatal mortality in the Samrakshan program of the Indian Radiological and Imaging Association (IRIA). Methods  The mean uterine artery (UtA) pulsatility index (PI) > 95th percentile, umbilical artery PI > 95th percentile, middle cerebral artery (MCA) PI < 5th percentile, and/or cerebroplacental ratio (CPR) < 5th percentile in the third trimester fetal Doppler study was considered as abnormal. The results of the fetal Doppler study closest to childbirth were considered for analysis. Late stillbirth (SB) was defined as a fetal loss between 28 and 36 gestation weeks and the term SB was defined as a fetal loss at ≥ 37 gestation weeks. Neonatal death was defined as the demise of a live-born baby within the first 28 days of life. Parameters of diagnostic effectiveness such as sensitivity, specificity, positive and negative predictive values and likelihood ratios, diagnostic odds ratio, and the area under receiver operator characteristic (AUROC) curve were assessed. Results  Screening of 1,326 pregnant women in the third trimester of pregnancy between September 2019 and February 2022, identified 308 (23.23%) abnormal Doppler studies, 11 (0.83%) SB, and 11 (0.84%) neonatal deaths. An abnormal Doppler study was significantly associated with late stillbirths (OR 37.2, 95% CI: 2.05, 674) but not with term SB (OR: 3.38, 95% CI: 0.76, 15) or neonatal deaths (OR 1.39, 95% CI: 0.40, 4.87). Mean UtA PI, umbilical artery PI, MCA PI, and CPR were significantly associated with late SB and not term SB. The AUROC of Doppler measures was excellent for late SB but did not show discriminatory ability for term SB or neonatal deaths. Conclusion  Integration of fetal Doppler with routine third-trimester antenatal scans can help identify pregnant women at high risk for late SB. The effectiveness of fetal Doppler to identify pregnant women at high risk for term SB and neonatal deaths needs further study on a larger sample size.

Full text links

For the best experience, use the Read mobile app

Group 7SearchHeart failure treatmentPapersTopicsCollectionsEffects of Sodium-Glucose Cotransporter 2 Inhibitors for the Treatment of Patients With Heart Failure Importance: Only 1 class of glucose-lowering agents-sodium-glucose cotransporter 2 (SGLT2) inhibitors-has been reported to decrease the risk of cardiovascular events primarily by reducingSeptember 1, 2017: JAMA CardiologyAssociations of albuminuria in patients with chronic heart failure: findings in the ALiskiren Observation of heart Failure Treatment study.CONCLUSIONS: Increased UACR is common in patients with heart failure, including non-diabetics. Urinary albumin creatininineJul, 2011: European Journal of Heart FailureRandomized Controlled TrialEffects of Liraglutide on Clinical Stability Among Patients With Advanced Heart Failure and Reduced Ejection Fraction: A Randomized Clinical Trial.Review

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app