Cardioverter-Defibrillator Reduces Mortality Risk in Eligible Ischemic and Non-ischemic Cardiomyopathy Patients: Sub-Analysis of the Multi-Center Improve SCA Study.

Indian Heart Journal 2023 January 32
BACKGROUND: & Objective: Despite the burden of sudden cardiac arrest (SCA) worldwide, implantable cardioverter-defibrillators (ICDs) are underutilized, particularly in Asia, Latin America, Eastern Europe, the Middle East, and Africa. The Improve SCA trial demonstrated that primary prevention (PP) patients in these regions benefit from an ICD or a cardiac resynchronization therapy defibrillator (CRT-D). We aimed to compare the rate of device therapy and mortality among ischemic and non-ischemic cardiomyopathy (ICM and NICM) PP patients who met guideline indications for ICD therapy and had an ICD/CRT-D implanted.

METHODS: Improve SCA was a prospective, non-randomized, non-blinded multicenter trial that enrolled patients from the above-mentioned regions. All-cause mortality and device therapy were examined by cardiomyopathy (ICM vs NICM) and implantation status. Cox proportional hazards methods were used, adjusting for factors affecting mortality risk.

RESULTS: Of 1,848 PP NICM patients, 1,007 (54.5%) received ICD/CRT-D, while 302 (52.1%) of 581 PP ICM patients received an ICD/CRT-D. The all-cause mortality rate at 3 years for NICM patients with and without an ICD/CRT-D was 13.1% and 18.3%, respectively (HR 0.51, 95% CI 0.38-0.68, p<0.001). Similarly, all-cause mortality at 3 years in ICM patients was 13.8% in those with a device and 19.9% in those without an ICD/CRT-D (HR 0.54, 95% CI 0.33-.0.88, p=0.011). The time to first device therapy, time to first shock, time to first antitachycardia pacing (ATP) therapy were not significantly different between groups (p≥0.263).

CONCLUSIONS: In this large data set of patients with a guideline-based PP ICD indication, defibrillator device implantation conferred a significant mortality benefit in both NICM and ICM patients. The rate of appropriate device therapy was also similar in both groups.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app