Add like
Add dislike
Add to saved papers

Development and validation of a multivariable model predicting the required catheter dwell time among mechanically ventilated critically ill patients in three randomized trials.

Annals of Intensive Care 2023 January 17
BACKGROUND: The anatomic site for central venous catheter insertion influences the risk of central venous catheter-related intravascular complications. We developed and validated a predictive score of required catheter dwell time to identify critically ill patients at higher risk of intravascular complications.

METHODS: We retrospectively conducted a cohort study from three multicenter randomized controlled trials enrolling consecutive patients requiring central venous catheterization. The primary outcome was the required catheter dwell time, defined as the period between the first catheter insertion and removal of the last catheter for absence of utility. Predictors were identified in the training cohort (3SITES trial; 2336 patients) through multivariable analyses based on the subdistribution hazard function accounting for death as a competing event. Internal validation was performed in the training cohort by 500 bootstraps to derive the CVC-IN score from robust risk factors. External validation of the CVC-IN score were performed in the testing cohort (CLEAN, and DRESSING2; 2371 patients).

RESULTS: The analysis was restricted to patients requiring mechanical ventilation to comply with model assumptions. Immunosuppression (2 points), high creatinine > 100 micromol/L (2 points), use of vasopressor (1 point), obesity (1 point) and older age (40-59, 1 point; ≥ 60, 2 points) were independently associated with the required catheter dwell time. At day 28, area under the ROC curve for the CVC-IN score was 0.69, 95% confidence interval (CI) [0.66-0.72] in the training cohort and 0.64, 95% CI [0.61-0.66] in the testing cohort. Patients with a CVC-IN score ≥ 4 in the overall cohort had a median required catheter dwell time of 24 days (versus 11 days for CVC-IN score < 4 points). The positive predictive value of a CVC-IN score ≥ 4 was 76.9% for > 7 days required catheter dwell time in the testing cohort.

CONCLUSION: The CVC-IN score, which can be used for the first catheter, had a modest ability to discriminate required catheter dwell time. Nevertheless, preference of the subclavian site may contribute to limit the risk of intravascular complications, in particular among ventilated patients with high CVC-IN score. Trials Registration NCT01479153, NCT01629550, NCT01189682.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app