PURPOSE: To identify imaging parameters that can help in the diagnosis of cardiac tamponade on non-electrocardiogram (ECG)-gated computed tomography (CT) of the chest.
MATERIALS AND METHODS: Retrospective analysis of 64 patients who had undergone CT and echocardiography for evaluation of cardiac tamponade. Of 64 patients, 34 were diagnosed with tamponade and underwent pericardiocentesis for further diagnosis and treatment. CT measurements obtained were: pericardial effusion (PeEff) pocket size in 6 locations (anterior, posterior, superior, inferior, right, and left lateral), pericardial thickening, diameters of the coronary sinus, upper superior vena cava, lower superior vena cava, and inferior vena cava. In addition, cardiac chamber sizes were measured. Subjective assessment of coronary sinus compression, pericardial enhancement, and pericardial thickening were also recorded.
RESULTS: Measurement of the sum of the right lateral and left lateral PeEff thickness resulted in 91.2% sensitivity and 86.7% specificity for cardiac tamponade with a threshold of 30 mm (receiver-operating characteristic area under the curve=0.94 [0.84 to 0.98], P<0.0001). Using the combination of inferior PeEff >16 mm, sum of right lateral and left lateral PeEff>30 mm, and presence of pericardial thickening resulted in 56% sensitivity and 100% specificity and positive predictive value for the determination of cardiac tamponade.
CONCLUSIONS: Our study suggests that CT measurements related to PeEff size and thickness aid in the diagnosis of cardiac tamponade.
MATERIALS AND METHODS: Retrospective analysis of 64 patients who had undergone CT and echocardiography for evaluation of cardiac tamponade. Of 64 patients, 34 were diagnosed with tamponade and underwent pericardiocentesis for further diagnosis and treatment. CT measurements obtained were: pericardial effusion (PeEff) pocket size in 6 locations (anterior, posterior, superior, inferior, right, and left lateral), pericardial thickening, diameters of the coronary sinus, upper superior vena cava, lower superior vena cava, and inferior vena cava. In addition, cardiac chamber sizes were measured. Subjective assessment of coronary sinus compression, pericardial enhancement, and pericardial thickening were also recorded.
RESULTS: Measurement of the sum of the right lateral and left lateral PeEff thickness resulted in 91.2% sensitivity and 86.7% specificity for cardiac tamponade with a threshold of 30 mm (receiver-operating characteristic area under the curve=0.94 [0.84 to 0.98], P<0.0001). Using the combination of inferior PeEff >16 mm, sum of right lateral and left lateral PeEff>30 mm, and presence of pericardial thickening resulted in 56% sensitivity and 100% specificity and positive predictive value for the determination of cardiac tamponade.
CONCLUSIONS: Our study suggests that CT measurements related to PeEff size and thickness aid in the diagnosis of cardiac tamponade.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app