Noninvasive monitoring of carbon dioxide: a comparison of the partial pressure of transcutaneous and end-tidal carbon dioxide with the partial pressure of arterial carbon dioxide.
Journal of Clinical Monitoring 1987 July
This study compares two noninvasive techniques for monitoring the partial pressure of carbon dioxide (PCO2) in 24 anesthetized adult patients. End-tidal PCO2 (PetCO2) and transcutaneous PCO2 (PtcCO2) were simultaneously monitored and compared with arterial PCO2 (PaCO2) determined by intermittent analysis of arterial blood samples. PETCO2 and PtcCO2 values were compared with PaCO2 values corrected to patient body temperature (PaCO2T) and PaCO2 values determined at a temperature of 37 degrees C (PaCO2). Linear regression was performed along with calculations of the correlation coefficient (r), bias, and precision of the four paired variables: PETCO2 versus PaCO2 and PaCO2T (n = 211), and PtcCO2 versus PaCO2 and PaCO2T (n = 233). Bias is defined as the mean difference between paired values, whereas precision is the standard deviation of the difference. The following values were found for r, bias, and +/- precision, respectively. PETCO2 versus PaCO2: 0.67, -7.8 mm Hg, +/- 6.1 mm Hg; PETCO2 versus PaCO2T: 0.73, -5.8 mm Hg, +/- 5.9 mm Hg; PtcCO2 versus PaCO2: 0.87, -1.6 mm Hg, +/- 4.3 mm Hg; PtcCO2 versus PaCO2T: 0.84, +0.7 mm Hg, +/- 4.8 mm Hg. Although each of these PCO2 variables is physiologically different, there is a significant correlation (P less than 0.001) between the noninvasively monitored values and the blood gas values. Temperature correction of the arterial values (PaCO2T) slightly improved the correlation, with respect to PETCO2, but it had the opposite effect for PtcCO2. In this study, the chief distinction between these two noninvasive monitors was that PETCO2 had a large negative bias, whereas PtcCO2 had a small bias. We conclude from these data that PtcCO2 may be used to estimate PaCO2 with an accuracy similar to that of PETCO2 in anesthetized patients.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app