Routine systematic prostate biopsies not replaced by magnetic resonance imaging-targeted biopsy.
Background: Multiparametric magnetic resonance imaging improves the performance of prostate cancer (PCa) diagnostics through a better selection of patients.
Objectives: The aim of the study was to study the detection rate (DR) of systematic and targeted cognitive biopsies in a cohort with the previous negative systematic biopsies. A secondary objective was to describe the value of prostate-specific antigen density (PSAd) in the detection of clinically significant PCa (CSPCa).
Methods: We designed a prospective, single-center, and comparative study to determine the DR of systematic and targeted cognitive biopsies. The clinical and pathological characteristics of each patient were described.
Results: A total of 111 patients with Prostate Imaging Reporting and Data System lesions > 3 were included in the study. PCa was detected in 41.4% (46 of 111 patients); 42 (91.3%) were detected by systematic biopsy and 30 (65.2%) by targeted biopsy. CSPCa was detected in 26 (23.4%), 23 (88.5%) by systematic biopsy, and 21 (76.9%) by targeted biopsy. PSAd > 0.15 was directly associated with CSPCa.
Conclusion: The detection of PCa by systematic biopsy in this series was higher than 80%; hence, its routine use should not be replaced by targeted biopsy, since it continues to be the cornerstone of the diagnosis in patients with prior negative biopsies.
Objectives: The aim of the study was to study the detection rate (DR) of systematic and targeted cognitive biopsies in a cohort with the previous negative systematic biopsies. A secondary objective was to describe the value of prostate-specific antigen density (PSAd) in the detection of clinically significant PCa (CSPCa).
Methods: We designed a prospective, single-center, and comparative study to determine the DR of systematic and targeted cognitive biopsies. The clinical and pathological characteristics of each patient were described.
Results: A total of 111 patients with Prostate Imaging Reporting and Data System lesions > 3 were included in the study. PCa was detected in 41.4% (46 of 111 patients); 42 (91.3%) were detected by systematic biopsy and 30 (65.2%) by targeted biopsy. CSPCa was detected in 26 (23.4%), 23 (88.5%) by systematic biopsy, and 21 (76.9%) by targeted biopsy. PSAd > 0.15 was directly associated with CSPCa.
Conclusion: The detection of PCa by systematic biopsy in this series was higher than 80%; hence, its routine use should not be replaced by targeted biopsy, since it continues to be the cornerstone of the diagnosis in patients with prior negative biopsies.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app