Comparison of capillary and venous blood sampling for routine coagulation assays.
Clinical Biochemistry 2022 June
OBJECTIVES: Capillary blood samples are generally assumed as unsuitable for coagulation testing since it is recognized that contamination with tissue factor and dilution with tissue fluid affects the coagulation assay. However, limited data is available about coagulations assays in which capillary blood sampling is compared to the standard venous blood withdrawal method. The aim of this study was to perform a method comparison between capillary and venous blood sampling for routine coagulation assays.
METHODS: Both venous and capillary (finger stick) blood samples were collected from 188 healthy volunteers and patients. In citrate plasma, International Normalized Ratio (INR), prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), fibrinogen, and D-dimer were measured according to routine protocols using the ACL-TOP 750 LAS (Werfen) coagulation analyzer. Regression analysis was performed and the mean relative difference between capillary and venous sampling was reflected to the total allowable error (TEa).
RESULTS: Strong correlations and acceptable variations, using the TEa as decision limit, were found for INR, PT, TT, fibrinogen, and D-dimer between capillary and venous sampling. However, capillary sampling resulted in significant shorter APTT values when using the standard APTT-SP Liquid reagent with a mean bias of -10.4% [95% CI -12.4 to -8.4].
CONCLUSION: Based on these results, capillary blood sampling proved to be an alternative blood withdrawal method for routine coagulation assays, with the exception of APTT, if a venipuncture is unavailable or undesired.
METHODS: Both venous and capillary (finger stick) blood samples were collected from 188 healthy volunteers and patients. In citrate plasma, International Normalized Ratio (INR), prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), fibrinogen, and D-dimer were measured according to routine protocols using the ACL-TOP 750 LAS (Werfen) coagulation analyzer. Regression analysis was performed and the mean relative difference between capillary and venous sampling was reflected to the total allowable error (TEa).
RESULTS: Strong correlations and acceptable variations, using the TEa as decision limit, were found for INR, PT, TT, fibrinogen, and D-dimer between capillary and venous sampling. However, capillary sampling resulted in significant shorter APTT values when using the standard APTT-SP Liquid reagent with a mean bias of -10.4% [95% CI -12.4 to -8.4].
CONCLUSION: Based on these results, capillary blood sampling proved to be an alternative blood withdrawal method for routine coagulation assays, with the exception of APTT, if a venipuncture is unavailable or undesired.
Full text links
Trending Papers
BTS clinical statement on aspiration pneumonia.Thorax 2023 Februrary
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app