Feasibility of portable capnometer for mechanically ventilated preterm infants in the delivery room

Masashi Hotta, Katsuya Hirata, Masatoshi Nozaki, Narutaka Mochizuki, Shinya Hirano, Kazuko Wada
European Journal of Pediatrics 2021 September 7
34494159
This study aimed to determine whether a specific portable capnometer (EMMA™) can facilitate the maintenance of an appropriate partial pressure of arterial carbon dioxide (PaCO2 ) in intubated preterm infants in the delivery room. This study included preterm infants with a gestational age of 26 + 0 to 31 + 6 weeks who required intubation in the delivery room. We prospectively identified 40 infants who underwent the EMMA™ monitoring intervention group and 43 infants who did not undergo monitoring (historical control group). PaCO2 was evaluated either at admission in the neonatal intensive care unit or at 2 h after birth. The proportion of infants with an appropriate PaCO2 (35-60 mmHg) was greater in the intervention group than in the control group (80% vs. 42%; p = 0.001). There were no significant differences in the rate of accidental extubation (5.0% vs. 7.0%, p = 1.00) or in the proportion of infants with an appropriate PaCO2 among infants whose birth weight was < 1000 g (54% vs. 40%, p = 0.49). However, among infants whose birth weight was ≥ 1000 g, the PaCO2 tended to be more appropriate in the intervention group than in the control group (93% vs. 44%; p < 0.001).Conclusion: The EMMA™ facilitated the maintenance of an appropriate PaCO2 for mechanically ventilated preterm infants, especially infants with birth weight ≥1000 g, in the delivery room. What is Known: • An inappropriate partial pressure of arterial carbon dioxide has been associated with intraventricular hemorrhage in preterm infants. • There is a need to appropriately control the partial pressure of arterial carbon dioxide in preterm infants. What is New: • This is the first report regarding the feasibility of a portable capnometer, the EMMA™, in the delivery room. • The EMMA™ may be considered a feasible monitoring device in the delivery room for intubated preterm infants, especially infants with birth weight ≥1000 g.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Trending Papers

Remove bar
Read by QxMD icon Read
34494159
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.