We have located links that may give you full text access.
The reference intervals of intraoperative posterior tibial nerve somatosensory evoked potentials.
Journal of Orthopaedic Science : Official Journal of the Japanese Orthopaedic Association 2021 July 28
BACKGROUND: A reference interval exists for posterior tibial nerve somatosensory evoked potentials (PTN-SEPs) in awake. However, the reference interval for intraoperative- PTN-SEPs (I-PTN-SEPs) remains unclear. As a substitute for PTN-SEPs in awake, we considered I-PTN-SEPs can provide functional information about the dorsal somatosensory system. No report evaluated the physiologic and analytical issues in the measurement of I-PTN-SEPs. We investigated the sources of variation and reference intervals for I-PTN-SEPs.
METHODS: We studied 143 patients with unilateral radiculopathy and without neurologic deficit who underwent surgery. Stimulation was delivered to the PTN at the ankle. The scalp recording electrode was placed at the Cz with a reference electrode located on the forehead at the Fz. SEPs were recorded from patients during electrical stimulation of the I-PTN.
RESULTS: P1 and N1 latencies showed significant positive linear correlations with age (P1 latency = 36.52 + 0.0814 × age, P = 0.00003; N1 latency = 46.21 + 0.081 × age, P = 0.00022), and body height (P1 latency = 16.94 + 14.91 × body height, P = 0.00000; N1 latency = 25.42 + 15.64 × body height, P = 0.00002). In contrast, I-PTN-SEPs amplitude showed no correlation with age or body height. The 95% confidence interval for I-PTN-SEPs amplitude, or the reference interval, was determined as 0.31-5.91 μV.
CONCLUSIONS: The lower normal limit value was 0.31 μV, and this reference interval may be useful to evaluate function of the posterior funiculus, such that as during surgery for patients with intramedullary tumor.
METHODS: We studied 143 patients with unilateral radiculopathy and without neurologic deficit who underwent surgery. Stimulation was delivered to the PTN at the ankle. The scalp recording electrode was placed at the Cz with a reference electrode located on the forehead at the Fz. SEPs were recorded from patients during electrical stimulation of the I-PTN.
RESULTS: P1 and N1 latencies showed significant positive linear correlations with age (P1 latency = 36.52 + 0.0814 × age, P = 0.00003; N1 latency = 46.21 + 0.081 × age, P = 0.00022), and body height (P1 latency = 16.94 + 14.91 × body height, P = 0.00000; N1 latency = 25.42 + 15.64 × body height, P = 0.00002). In contrast, I-PTN-SEPs amplitude showed no correlation with age or body height. The 95% confidence interval for I-PTN-SEPs amplitude, or the reference interval, was determined as 0.31-5.91 μV.
CONCLUSIONS: The lower normal limit value was 0.31 μV, and this reference interval may be useful to evaluate function of the posterior funiculus, such that as during surgery for patients with intramedullary tumor.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app