Role of ultrasound in manual detorsion for testicular torsion.
Journal of Clinical Ultrasound : JCU 2021 July 9
PURPOSE: Manual detorsion can be performed for testicular torsion before scrotal exploration. Using sonographic findings, this study investigated the need for additional treatments after manual detorsion for testicular torsion.
METHODS: This study evaluated 13 retrospective cases of testicular torsion subjected to manual detorsion. Manual detorsion was classified as failure or success based on residual spermatic cord twist. The following sonographic findings of the affected testis were compared using the Fisher exact test: whirlpool sign, horizontal or altered lie, and hypoperfusion.
RESULTS: Manual detorsion failed in five patients. There was a significant difference in the incidence of the whirlpool sign between the two groups (present/absent sign in the failure vs. success groups: 4/1 vs. 0/8, p = 0.007). Horizontal or altered lie and hypoperfusion in the affected testis were not significantly different between groups (5/0 vs. 3/4, p = 0.07, one case excluded, and 5/0 vs. 4/4, p = 0.10, respectively).
CONCLUSIONS: Ultrasound findings after manual detorsion, particularly, the whirlpool sign, were useful for planning subsequent treatment such as additional manual detorsion or surgical intervention. The testicular axis and the perfusion of the twisted testis may not recover to normal after successful manual detorsion, but if they recover, this procedure could be judged a success.
METHODS: This study evaluated 13 retrospective cases of testicular torsion subjected to manual detorsion. Manual detorsion was classified as failure or success based on residual spermatic cord twist. The following sonographic findings of the affected testis were compared using the Fisher exact test: whirlpool sign, horizontal or altered lie, and hypoperfusion.
RESULTS: Manual detorsion failed in five patients. There was a significant difference in the incidence of the whirlpool sign between the two groups (present/absent sign in the failure vs. success groups: 4/1 vs. 0/8, p = 0.007). Horizontal or altered lie and hypoperfusion in the affected testis were not significantly different between groups (5/0 vs. 3/4, p = 0.07, one case excluded, and 5/0 vs. 4/4, p = 0.10, respectively).
CONCLUSIONS: Ultrasound findings after manual detorsion, particularly, the whirlpool sign, were useful for planning subsequent treatment such as additional manual detorsion or surgical intervention. The testicular axis and the perfusion of the twisted testis may not recover to normal after successful manual detorsion, but if they recover, this procedure could be judged a success.
Full text links
Trending Papers
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app