We have located links that may give you full text access.
JOURNAL ARTICLE
MULTICENTER STUDY
Paclitaxel-Coated Balloons for the Treatment of Symptomatic Central Venous Stenosis in Vascular Access: Results From a European, Multicenter, Single-Arm Retrospective Analysis.
Journal of Endovascular Therapy 2021 June
INTRODUCTION: This was a European, multicenter, investigator-initiated and run, single-arm retrospective analysis to assess the safety and the clinical benefit of the use of paclitaxel-coated balloon (PCB) for the treatment of symptomatic central venous stenosis (CVS).
MATERIALS AND METHODS: Eleven centers from 7 countries across Europe, submitted 86 cases performed during the period between October 2015 and June 2018. Minimum follow-up was 6 months. Patient baseline demographics and procedural details were collected. Mean age was 62.6 years (SD 15.2 years). Median vascular access age was 3.0 years (IQR 1.2-4.8 years). A total of 55 were arteriovenous fistulas (64%) the rest arteriovenous grafts (31/86, 36%). Vessels treated were 43 subclavian veins, 42 brachiocephalic veins and 1 superior vena cava. Median drug-coated balloon diameter was 10 mm (IQR 8-12 mm). Primary outcome measures were clinically assessed intervention-free period (IFP) of the treated segment at 6 months and procedure-related minor and major complications. Secondary outcome measures included access circuit survival, patient survival, and the investigation of independent factors that influence the IFP.
RESULTS: IFP was 62.7% at 6 months. Median patient follow-up time was 1.0 year (IQR 0.5-2.2 years). There was 1 minor complication (1/86; 1.2%) and no major complications. Access circuit survival was 87.7% at 6 months. Patient survival was 79.7% at 2 years according to Kaplan-Meier survival analysis. Higher balloon diameters significantly favored IFP [HR 0.71 (0.55-0.92), p=0.006; 5-7 mm group vs 8-12 mm group, p=0.025].
CONCLUSION: In this analysis, use of PCBs for the treatment of symptomatic CVS was safe. Efficacy was comparable to previous trials. Increased balloon size had a significant effect on patency rates.
MATERIALS AND METHODS: Eleven centers from 7 countries across Europe, submitted 86 cases performed during the period between October 2015 and June 2018. Minimum follow-up was 6 months. Patient baseline demographics and procedural details were collected. Mean age was 62.6 years (SD 15.2 years). Median vascular access age was 3.0 years (IQR 1.2-4.8 years). A total of 55 were arteriovenous fistulas (64%) the rest arteriovenous grafts (31/86, 36%). Vessels treated were 43 subclavian veins, 42 brachiocephalic veins and 1 superior vena cava. Median drug-coated balloon diameter was 10 mm (IQR 8-12 mm). Primary outcome measures were clinically assessed intervention-free period (IFP) of the treated segment at 6 months and procedure-related minor and major complications. Secondary outcome measures included access circuit survival, patient survival, and the investigation of independent factors that influence the IFP.
RESULTS: IFP was 62.7% at 6 months. Median patient follow-up time was 1.0 year (IQR 0.5-2.2 years). There was 1 minor complication (1/86; 1.2%) and no major complications. Access circuit survival was 87.7% at 6 months. Patient survival was 79.7% at 2 years according to Kaplan-Meier survival analysis. Higher balloon diameters significantly favored IFP [HR 0.71 (0.55-0.92), p=0.006; 5-7 mm group vs 8-12 mm group, p=0.025].
CONCLUSION: In this analysis, use of PCBs for the treatment of symptomatic CVS was safe. Efficacy was comparable to previous trials. Increased balloon size had a significant effect on patency rates.
Full text links
Trending Papers
Acute and non-acute decompensation of liver cirrhosis (47/130).Liver International : Official Journal of the International Association for the Study of the Liver 2024 March 2
Guide to Utilization of the Microbiology Laboratory for Diagnosis of Infectious Diseases: 2024 Update by the Infectious Diseases Society of America (IDSA) and the American Society for Microbiology (ASM).Clinical Infectious Diseases 2024 March 6
Ten Influential Point-of-Care Ultrasound Papers: 2023 in Review.Journal of Intensive Care Medicine 2024 Februrary 20
Administration of methylene blue in septic shock: pros and cons.Critical Care : the Official Journal of the Critical Care Forum 2024 Februrary 17
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app