We have located links that may give you full text access.
SSEP amplitude accurately predicts both good and poor neurological outcome early after cardiac arrest; a post-hoc analysis of the ProNeCA multicentre study.
Resuscitation 2021 April 3
AIM: To assess if, in comatose resuscitated patients, the amplitude of the N20 wave (N20amp) of somatosensory evoked potentials (SSEP) can predict 6-months neurological outcome.
SETTING: Multicentre study in 13 Italian intensive care units.
METHODS: The N20amp in microvolts (μV) was measured at 12 h, 24 h, and 72 h from cardiac arrest, along with pupillary reflex (PLR) and a 30-min EEG classified according to the ACNS terminology. Sensitivity and false positive rate (FPR) of N20amp alone or in combination were calculated.
RESULTS: 403 patients (age 69[58-68] years) were included. At 12 h, an N20amp >3 μV predicted good neurological outcome (Cerebral Performance Categories [CPC] 1-2) with 61[50-72]% sensitivity and 11[6-18]% FPR. Combining it with a benign (continuous or nearly continuous) EEG increased sensitivity to 91[82-96]%. For poor outcome (CPC 3-5), an N20Amp ≤0.38 μV, ≤0.73 μV and ≤1.01 μV at 12 h, 24 h, and 72 h, respectively, had 0% FPR with sensitivity ranging from 61[51-69]% and 82[76-88]%. Sensitivity was higher than that of a bilaterally absent N20 at all time points. At 12 h and 24 h, a highly malignant (suppression or burst-suppression) EEG and bilaterally absent PLR achieved 0% FPR only when combined with SSEP. A combination of all three predictors yielded a 0[0-4]% FPR, with maximum sensitivity of 44[36-53]%.
CONCLUSION: At 12 h from arrest, a high N20Amp predicts good outcome with high sensitivity, especially when combined with benign EEG. At 12 h and 24 h from arrest a low-voltage N20amp has a high sensitivity and is more specific than EEG or PLR for predicting poor outcome.
SETTING: Multicentre study in 13 Italian intensive care units.
METHODS: The N20amp in microvolts (μV) was measured at 12 h, 24 h, and 72 h from cardiac arrest, along with pupillary reflex (PLR) and a 30-min EEG classified according to the ACNS terminology. Sensitivity and false positive rate (FPR) of N20amp alone or in combination were calculated.
RESULTS: 403 patients (age 69[58-68] years) were included. At 12 h, an N20amp >3 μV predicted good neurological outcome (Cerebral Performance Categories [CPC] 1-2) with 61[50-72]% sensitivity and 11[6-18]% FPR. Combining it with a benign (continuous or nearly continuous) EEG increased sensitivity to 91[82-96]%. For poor outcome (CPC 3-5), an N20Amp ≤0.38 μV, ≤0.73 μV and ≤1.01 μV at 12 h, 24 h, and 72 h, respectively, had 0% FPR with sensitivity ranging from 61[51-69]% and 82[76-88]%. Sensitivity was higher than that of a bilaterally absent N20 at all time points. At 12 h and 24 h, a highly malignant (suppression or burst-suppression) EEG and bilaterally absent PLR achieved 0% FPR only when combined with SSEP. A combination of all three predictors yielded a 0[0-4]% FPR, with maximum sensitivity of 44[36-53]%.
CONCLUSION: At 12 h from arrest, a high N20Amp predicts good outcome with high sensitivity, especially when combined with benign EEG. At 12 h and 24 h from arrest a low-voltage N20amp has a high sensitivity and is more specific than EEG or PLR for predicting poor outcome.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app