Evaluation of cochlear functions in infants exposed to SARS-CoV-2 intrauterine.
American Journal of Otolaryngology 2021 July
PURPOSE: The novel coronavirus (SARS-CoV-2) caused an acute respiratory illness named COVID-19 and the disease spread all over the World. Fever, cough, fatigue, gastrointestinal infection symptoms form the main clinical symptoms. Pregnants and newborns form a vulnerable population and urgent measures must be addressed. Studies about the effect of COVID-19 on pregnant women, developing fetuses, and infants are limited. Various viral diseases can cause congenital or acquired, unilateral or bilateral hearing loss.
METHODS: 37 infants whose mother was pregnant between March 2020 and December 2020 and were born after the diagnosis of COVID- 19 during pregnancy and 36 healthy infants were included in the study. Transient evoked otoacoustic emission (TEOAE), distortion product otoacoustic emission (DPOAE) and contralateral suppression of OAE (CLS OAE) tests were performed on all infants.
RESULTS: According to the TEOAE results of patients and controls in the silent a statistically significant difference was observed between the two groups at 3 kHz and 4 kHz (p < 0.05). Contralateral suppression of OAE test results of patients and controls a statistically significant difference was found in all frequencies (p< 0.05). Suppression was much more effective at all frequencies in the normal group than patient group. This difference was found to be more significant at higher frequencies (2,3 and 4 kHz) (p < 0.001).
CONCLUSIONS: Our results suggest an insufficiency in medial olivocochlear efferent system in infants exposed to SARS-CoV-2 intrauterine. Cochlear functions should be examined in infants whose mothers had COVID-19.
METHODS: 37 infants whose mother was pregnant between March 2020 and December 2020 and were born after the diagnosis of COVID- 19 during pregnancy and 36 healthy infants were included in the study. Transient evoked otoacoustic emission (TEOAE), distortion product otoacoustic emission (DPOAE) and contralateral suppression of OAE (CLS OAE) tests were performed on all infants.
RESULTS: According to the TEOAE results of patients and controls in the silent a statistically significant difference was observed between the two groups at 3 kHz and 4 kHz (p < 0.05). Contralateral suppression of OAE test results of patients and controls a statistically significant difference was found in all frequencies (p< 0.05). Suppression was much more effective at all frequencies in the normal group than patient group. This difference was found to be more significant at higher frequencies (2,3 and 4 kHz) (p < 0.001).
CONCLUSIONS: Our results suggest an insufficiency in medial olivocochlear efferent system in infants exposed to SARS-CoV-2 intrauterine. Cochlear functions should be examined in infants whose mothers had COVID-19.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app