We have located links that may give you full text access.
The impact of a novel operational readiness response model on the environmental cleanliness of emergency ambulances.
Prehospital Emergency Care 2021 Februrary 3
Objectives Environmental cleanliness of emergency ambulances may be associated with increased risk of healthcare acquired infection (HAI). Surface cleanliness, measured using adenosine triphosphate (ATP) testing, has been demonstrated to correlate with potentially harmful levels of microbial pathogens. In most ambulance services, environmental cleanliness of ambulances and the equipment within them is the responsibility of paramedics. In 2016 NSW Ambulance introduced the Make Ready Model (MRM), in which ambulances are systematically cleaned by non-clinical support staff at the end of each shift. This prospective study aimed to 1) provide a baseline level of ambulance cleanliness; and 2) compare the MRM to a standard cleaning model (SCM). Methods A prospective comparative study was conducted comparing cleanliness of ambulances in the SCM to those in the MRM. Adenosine-triphosphate (ATP) bioluminescence testing was performed in a pseudo-randomised sample of ambulances. Six 'high touch' areas within each ambulance were systematically sampled. Testing occurred without warning to operational staff. The primary outcome was 'overall bioburden' (OB)' measured in radiant light units ('RLU'). Non-parametric tests were used to assess differences in RLU values between each of the test points, while Poisson multivariate regression was used to compare median overall bioburden between the two groups, adjusting for the confounder variable of 14-day ambulance workload. Results Sixty-eight ambulances were sampled, 32 from the SCM and 36 from the MRM. Median surface bioburden was significantly lower in the MRM for four of the six test points (preparation table, mobile data terminal, stretcher handles and steering wheel). For the primary outcome of overall bioburden, the unadjusted MRM OB was 35% lower than for the SCM group (RR 0.65 (0.64-0.66; p < 0.01)). After adjusting for the significant confounding variable of 14-day workload, the OB was 38% lower for the MRM group (ARR 0.68 (0.61-0.63; p < 0.001)). Conclusion The innovative MRM cleaning system was associated with significantly improved cleanliness in frontline emergency ambulances. The magnitude of improvement in cleanliness suggests this cleaning model has the potential to make a major contribution to infection control strategies in paramedicine. Future research should focus on cost effectiveness of the MRM and its applicability to regional and remote ambulance service operations.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app