New possibilities: the LockDown device for distal clavicle fractures.

JSES international. 2020 December
Background and hypothesis: The majority of distal clavicle fractures are displaced fractures and constitute a treatment challenge because they have a 30% chance of delayed union or nonunion. Although several options for surgical reconstruction have been described, in patients with a comminuted and/or small distal fragment, these reconstructive options have proved to be prone to failure. Moreover, secondary surgery for removal is necessary in most cases. We hypothesized that the LockDown device, a braided synthetic ligament device, combined with resection of the distal fracture fragment is a suitable alternative in specified patients with distal clavicle fractures.

Methods: Eleven patients with distal clavicle fractures were treated with distal fracture resection and the LockDown procedure. All patients underwent regular follow-up with data collection; additionally, 7 were assessed at 1-year follow-up according to the study protocol. On the basis of radiography, these patients had a clear coracoclavicular ligament disruption and subsequent cranial dislocation of the medial fragment. Regular follow-up was performed at 6 weeks, 3 months, and 6 months. Control radiographs were taken at 3 and 6 months. Furthermore, the 7 enrolled patients were assessed at 1 year, when the Disabilities of the Arm, Shoulder and Hand score, Constant shoulder score, Nottingham Clavicle Score, and range of motion were recorded. Residual pain was ascertained by a visual analog scale score.

Results: In total, 11 patients were treated with distal clavicle resection and the LockDown procedure. Eight patients underwent surgery within 3 weeks after presentation at the emergency department. The other 3 patients were operated on after a trial of conservative treatment (due to persisting pain and delayed union). None of the patients had postoperative complications. At 3 months, 9 of the 11 patients had made a full recovery.

Discussion: All 11 patients had good short-term clinical outcomes. None showed acromioclavicular instability. Furthermore, secondary surgery was avoided, and hardware complications did not occur. In low-demand patients or patients with a high risk of nonunion, this technique may be a favorable alternative to other known techniques.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app