Monitoring the patient for a safe-assisted ventilation.
Current Opinion in Critical Care 2021 Februrary 2
PURPOSE OF REVIEW: A growing evidence shows that injurious spontaneous breathing, either too weak or too strong, may injure lung and diaphragm. The purpose of review is to understand why we need monitoring for safe spontaneous breathing, and to know the target value of each monitoring to preserve safe spontaneous breathing during assisted ventilation.
RECENT FINDINGS: Lung protection sometimes goes counter to diaphragm protection. For instance, silence of respiratory muscle activity is necessary to minimize lung injury from vigorous spontaneous effort in acute respiratory distress syndrome, but it may also have a risk of diaphragm atrophy. Thus, our current goal is to preserve spontaneous breathing activity at modest level during assisted ventilation. To achieve this goal, several monitoring/techniques are now available at the bedside (e.g., plateau pressure measurement, airway occlusion pressure, end-expiratory airway occlusion, esophageal balloon manometry, electrical impedance tomography). The target value of each monitoring is vigorously being investigated, facilitating 'safe' spontaneous breathing effort from the perspective of lung and diaphragm protection.
SUMMARY: We summarize why we need monitoring for safe spontaneous breathing during assisted ventilation and what the target value of each monitoring is to facilitate 'safe' spontaneous breathing during assisted ventilation.
RECENT FINDINGS: Lung protection sometimes goes counter to diaphragm protection. For instance, silence of respiratory muscle activity is necessary to minimize lung injury from vigorous spontaneous effort in acute respiratory distress syndrome, but it may also have a risk of diaphragm atrophy. Thus, our current goal is to preserve spontaneous breathing activity at modest level during assisted ventilation. To achieve this goal, several monitoring/techniques are now available at the bedside (e.g., plateau pressure measurement, airway occlusion pressure, end-expiratory airway occlusion, esophageal balloon manometry, electrical impedance tomography). The target value of each monitoring is vigorously being investigated, facilitating 'safe' spontaneous breathing effort from the perspective of lung and diaphragm protection.
SUMMARY: We summarize why we need monitoring for safe spontaneous breathing during assisted ventilation and what the target value of each monitoring is to facilitate 'safe' spontaneous breathing during assisted ventilation.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app