We have located links that may give you full text access.
Role of New Hydrophilic Surfaces on Early Success Rate and Implant Stability: 1-Year Post-loading Results of a Multicenter, Split-Mouth, Randomized Controlled Trial.
European Journal of Dentistry 2020 November 27
OBJECTIVE: To compare early implant failure and implant stability of one-stage Hiossen ET III implants with its new hydrophilic (NH) surface, compared with Hiossen ET III implants with the sandblasted and acid-etched (SA) surface at 1-year follow-up.
MATERIALS AND METHODS: This study was designed as a split-mouth, multicenter randomized controlled trial aimed to compare SA surface implants (SA group) and NH surface, (NH group). Outcomes were implant and prosthetic survival rates, complications, the insertion torque at implant placement, and implant stability quotient (ISQ) values.
RESULTS: Twenty-nine patients (mean age 59.9 ± 11.3 years) were treated and followed up to 1 year after loading. No patient dropped out. Fifty-eight implants (29 SA group and 29 NH group) were placed. No implants or prostheses failed and no complications were experienced during follow-up. The mean insertion torque was 40.5 ± 3.23 (38.17-41.83) Ncm in the SA group and 40.48 ± 3.49 (38.02-41.98) Ncm in the NH group ( p = 0.981). There was a statistically significant difference at the second week (T2) with higher values in the NH group ( p = 0.041). Similar results were found in the maxilla ( p = 0.045), but not in the mandible ( p = 0.362). A positive correlation was found between initial insertion torque and ISQ with higher value in the NH group (0.73 vs. 0.66).
CONCLUSIONS: NH implants are a viable alternative to SA surface, as they seem to avoid the ISQ drop during the bone remodeling phase.
MATERIALS AND METHODS: This study was designed as a split-mouth, multicenter randomized controlled trial aimed to compare SA surface implants (SA group) and NH surface, (NH group). Outcomes were implant and prosthetic survival rates, complications, the insertion torque at implant placement, and implant stability quotient (ISQ) values.
RESULTS: Twenty-nine patients (mean age 59.9 ± 11.3 years) were treated and followed up to 1 year after loading. No patient dropped out. Fifty-eight implants (29 SA group and 29 NH group) were placed. No implants or prostheses failed and no complications were experienced during follow-up. The mean insertion torque was 40.5 ± 3.23 (38.17-41.83) Ncm in the SA group and 40.48 ± 3.49 (38.02-41.98) Ncm in the NH group ( p = 0.981). There was a statistically significant difference at the second week (T2) with higher values in the NH group ( p = 0.041). Similar results were found in the maxilla ( p = 0.045), but not in the mandible ( p = 0.362). A positive correlation was found between initial insertion torque and ISQ with higher value in the NH group (0.73 vs. 0.66).
CONCLUSIONS: NH implants are a viable alternative to SA surface, as they seem to avoid the ISQ drop during the bone remodeling phase.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app