Your institution is subscribed to Read Institutional Edition. Log in or Sign Up to read full text articles.

JOURNAL ARTICLE

Long-term outcome of perimembranous VSD closure using the Nit-Occlud® Lê VSD coil system

Rainer Kozlik-Feldmann, Avraham Lorber, Horst Sievert, Peter Ewert, Christian Jux, Götz C Müller, Robert Dalla Pozza, Mustafa Yigitbasi, Dietmar Schranz, Angelika Lindinger, Omar Galal, Thomas Meinertz
Clinical Research in Cardiology: Official Journal of the German Cardiac Society 2021, 110 (3): 382-390
33128576

OBJECTIVE: This study presents data from the admission trial to show the feasibility, safety and effectiveness of the Nit-Occlud® Lê VSD in the treatment of perimembranous ventricular septal defects with an aneurysmal configuration and a diameter up to 8 mm.

BACKGROUND: The majority of ventricular septal defects (VSD) are still closed surgically, while a less invasive transcatheter treatment by closure devices is available. Device-based closure is reported to be associated with the risk of complete atrio-ventricular block, especially with double-disc devices in perimembranous defects.

METHODS: In six tertiary centers in Germany and Israel, an interventional closure of a periembranous VSD was attempted in 88 patients using the Nit-Occlud® Lê VSD.

RESULTS: The interventional VSD closure was performed in 85 patients. Patients had a median age of 8.0 (2-65) years and a median body weight of 26.7 (10-109) kg. A complete closure of the defects was achieved in 85.4% 2 weeks after device implantation, in 88.9% after three months and in 98.6% at the 5-year follow-up. There was no incidence of death during the study nor did any patient suffer of permanent atrio-ventricular block of higher degree. Serious adverse events, by definition, are potentially life-threatening or require surgery to correct, while major serious events require medical or transcatheter intervention to correct. The study results exhibit a serious adverse event rate of 3.5% (3/85 patients) and a major adverse event rate of 5.9% (5/85 patients).

CONCLUSION: The Nit-Occlud® Lê VSD coil offers the possibility of an effective and safe approach in patients with aneurysmal perimembranous ventricular septal defects.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
33128576
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.