We have located links that may give you full text access.
COMPARATIVE STUDY
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Quantitative measurements of cerebral blood flow using SPECT and [99mTc]-d,l-HM-PAO compared to xenon-133.
Journal of Cerebral Blood Flow and Metabolism 1988 December
The uptake and retention in a 2 cm thick brain section was recorded serially by SPECT after i.v. injection of [99mTc]-d,l-HM-PAO (HM-PAO). In 16 patients, the fraction of the administered dose retained by the brain was 5.2 +/- 1%, showing a peak after 40-50s, then decreasing by 10% within the first 10 min and then by only 0.4% per hour. The image contrast was measured in each patient as the regional hemispheric asymmetry difference in percent of the highest value of the two regions. It decreased from 31% at 30-40 s to 25% at 10 min. At 24 h, a value of 19% was reached. Using the images obtained at 10 min after injection, a region to region comparison of the original and corrected HM-PAO images to the xenon-133 regional cerebral blood flow (rCBF) images was performed. Forty-four patients with stroke, epilepsy, dementia, basal ganglia disease, and tumors and control subjects were included in this comparison. The algorithm proposed by Lassen et al. was used to correct the original images for back diffusion of tracer (brain to blood); a good correlation very close to the line of identity between the corrected HM-PAO and xenon-133 data was obtained when using a conversion/clearance ratio of 1.5 and when the noninvolved hemisphere was used as a reference region (r = 0.86, p less than 0.0001). Serial arterial and cerebral venous blood sampling was performed over 10 min following i.v. injection of HM-PAO in six patients. An overall brain retention fraction of 0.37 +/- 0.03 (mean +/- SEM) was calculated from the data. An average CBF of 0.62 +/- 0.12 ml/g/min was determined on the basis of the Fick principle; this compared to a value of 0.59 +/- 0.09 ml/g/min (mean +/- SEM) measured by the xenon-133 inhalation method. The two sets of CBF values correlated linearly with a correlation coefficient of 0.97 (p less than 0.01). Inserting the average CBF value for the hemisphere as measured by the Fick principle into the algorithm described by Lassen et al. yields absolute rCBF values (ml/g/min) directly from the corrected HM-PAO images.(ABSTRACT TRUNCATED AT 400 WORDS)
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app