COMPARATIVE STUDY
JOURNAL ARTICLE

Quantitative measurements of cerebral blood flow using SPECT and [99mTc]-d,l-HM-PAO compared to xenon-133

A R Andersen, H H Friberg, J F Schmidt, S G Hasselbalch
Journal of Cerebral Blood Flow and Metabolism 1988, 8 (6): S69-81
3263980
The uptake and retention in a 2 cm thick brain section was recorded serially by SPECT after i.v. injection of [99mTc]-d,l-HM-PAO (HM-PAO). In 16 patients, the fraction of the administered dose retained by the brain was 5.2 +/- 1%, showing a peak after 40-50s, then decreasing by 10% within the first 10 min and then by only 0.4% per hour. The image contrast was measured in each patient as the regional hemispheric asymmetry difference in percent of the highest value of the two regions. It decreased from 31% at 30-40 s to 25% at 10 min. At 24 h, a value of 19% was reached. Using the images obtained at 10 min after injection, a region to region comparison of the original and corrected HM-PAO images to the xenon-133 regional cerebral blood flow (rCBF) images was performed. Forty-four patients with stroke, epilepsy, dementia, basal ganglia disease, and tumors and control subjects were included in this comparison. The algorithm proposed by Lassen et al. was used to correct the original images for back diffusion of tracer (brain to blood); a good correlation very close to the line of identity between the corrected HM-PAO and xenon-133 data was obtained when using a conversion/clearance ratio of 1.5 and when the noninvolved hemisphere was used as a reference region (r = 0.86, p less than 0.0001). Serial arterial and cerebral venous blood sampling was performed over 10 min following i.v. injection of HM-PAO in six patients. An overall brain retention fraction of 0.37 +/- 0.03 (mean +/- SEM) was calculated from the data. An average CBF of 0.62 +/- 0.12 ml/g/min was determined on the basis of the Fick principle; this compared to a value of 0.59 +/- 0.09 ml/g/min (mean +/- SEM) measured by the xenon-133 inhalation method. The two sets of CBF values correlated linearly with a correlation coefficient of 0.97 (p less than 0.01). Inserting the average CBF value for the hemisphere as measured by the Fick principle into the algorithm described by Lassen et al. yields absolute rCBF values (ml/g/min) directly from the corrected HM-PAO images.(ABSTRACT TRUNCATED AT 400 WORDS)

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Trending Papers

Remove bar
Read by QxMD icon Read
3263980
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.