The effect of intrapartum oxygen supplementation on category II fetal monitoring.

BACKGROUND: Maternal oxygen administration is a widely used intrauterine resuscitation technique for fetuses with category II electronic fetal monitoring patterns, despite a paucity of evidence on its ability to improve electronic fetal monitoring patterns.

OBJECTIVE: This study investigated the effect of intrapartum oxygen administration on Category II electronic fetal monitoring patterns.

STUDY DESIGN: This is a secondary analysis of a randomized trial conducted in 2016-2017, in which patients with fetuses at ≥37 weeks' gestation in active labor with category II electronic fetal monitoring patterns were assigned to 10 L/min of oxygen by face mask or room air until delivery. Trained obstetrical research nurses blinded to allocation extracted electronic fetal monitoring data. The primary outcome was a composite of high-risk category II features including recurrent variable decelerations, recurrent late decelerations, prolonged decelerations, tachycardia, or minimal variability 60 minutes after randomization to room air or oxygen. Secondary outcomes included individual components of the composite high-risk category II features, resolution of recurrent decelerations within 60 minutes of randomization, and total deceleration area. The outcomes between the room air and oxygen groups were compared using univariable statistics. Time-to-event analysis was used to compare time to resolution of recurrent decelerations between the groups. Paired analysis was used to compare the pre- and postrandomization outcomes within each group.

RESULTS: All 114 randomized patients (57 room air and 57 oxygen) were included in this analysis. There was no difference in resolution of recurrent decelerations within 60 minutes between the oxygen and room air groups (75.4% vs 86.0%; P=.15). The room air and oxygen groups had similar rates of composite high-risk category II features including recurrent variable decelerations, recurrent late decelerations, prolonged decelerations, tachycardia, and minimal variability 60 minutes after randomization. Time to resolution of recurrent decelerations and total deceleration area were similar between the room air and oxygen groups. Among patients who received oxygen, there was no difference in the electronic fetal monitoring patterns pre- and postrandomization. Similar findings were observed in the electronic fetal monitoring patterns pre- and postrandomization in room air patients.

CONCLUSION: Intrapartum maternal oxygen administration for category II electronic fetal monitoring patterns did not resolve high-risk category II features or hasten the resolution of recurrent decelerations. These results suggest that oxygen administration has no impact on improving category II electronic fetal monitoring patterns.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app