Design and Implementation of an Anti-Factor Xa Heparin Monitoring Protocol.
AACN Advanced Critical Care 2020 June 16
BACKGROUND: The VA Northeast Ohio Healthcare System introduced a new nurse-driven anti-factor Xa (anti-Xa) protocol for monitoring unfractionated heparin to replace the previous activated partial thromboplastin time protocol.
OBJECTIVE: To design, implement, and evaluate the efficacy of the anti-Xa monitoring protocol.
METHODS: An interdisciplinary team of providers collaborated to develop and implement a nurse-driven, facility-wide anti-factor Xa protocol for monitoring unfractionated heparin therapy. The effectiveness of this protocol was evaluated by retrospective analysis.
RESULTS: We reviewed 100 medical records for compliance with the new anti-Xa monitoring protocol. We then evaluated 178 patients whose anticoagulation was monitored with the anti-Xa assay to determine the time to therapeutic range. We found that 80% of patients receiving the anti-Xa protocol achieved therapeutic anticoagulation within 24 hours, as compared with 54% of patients receiving the activated partial thromboplastin time protocol (P < .001). Protocol conversion also yielded a decrease in blood draws, dose adjustments, and potential calculation errors.
CONCLUSIONS: Monitoring intravenous heparin therapy with the anti-Xa assay rather than activated partial thromboplastin time resulted in a shorter time to therapeutic anticoagulation, longer maintenance of therapeutic levels, and fewer laboratory tests and heparin dosage changes. We believe the current practice of monitoring heparin treatment with activated partial thromboplastin time assays should be reexamined.
OBJECTIVE: To design, implement, and evaluate the efficacy of the anti-Xa monitoring protocol.
METHODS: An interdisciplinary team of providers collaborated to develop and implement a nurse-driven, facility-wide anti-factor Xa protocol for monitoring unfractionated heparin therapy. The effectiveness of this protocol was evaluated by retrospective analysis.
RESULTS: We reviewed 100 medical records for compliance with the new anti-Xa monitoring protocol. We then evaluated 178 patients whose anticoagulation was monitored with the anti-Xa assay to determine the time to therapeutic range. We found that 80% of patients receiving the anti-Xa protocol achieved therapeutic anticoagulation within 24 hours, as compared with 54% of patients receiving the activated partial thromboplastin time protocol (P < .001). Protocol conversion also yielded a decrease in blood draws, dose adjustments, and potential calculation errors.
CONCLUSIONS: Monitoring intravenous heparin therapy with the anti-Xa assay rather than activated partial thromboplastin time resulted in a shorter time to therapeutic anticoagulation, longer maintenance of therapeutic levels, and fewer laboratory tests and heparin dosage changes. We believe the current practice of monitoring heparin treatment with activated partial thromboplastin time assays should be reexamined.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app