Biomechanical evaluation of two alternative techniques to the Goel-Harms technique for atlantoaxial fixation: C1 lateral mass-C2 bicortical translaminar screw fixation and C1 lateral mass-C2/3 transarticular screw fixation.

OBJECTIVE: The authors conducted a study to investigate the biomechanical feasibility and stability of C1 lateral mass-C2 bicortical translaminar screw (C1LM-C2TL) fixation, C1 lateral mass-C2/3 transarticular screw (C1LM-C2/3TA) fixation, and C1LM-C2/3TA fixation with transverse cross-links (C1LM-C2/3TACL) as alternative techniques to the Goel-Harms technique (C1 lateral mass-C2 pedicle screw [C1LM-C2PS] fixation) for atlantoaxial fixation.

METHODS: Eight human cadaveric cervical spines (occiput-C7) were tested using an industrial robot. Pure moments that were a maximum of 1.5 Nm were applied in flexion-extension (FE), lateral bending (LB), and axial rotation (AR). The specimens were first tested in the intact state and followed by destabilization (a type II odontoid fracture) and fixation as follows: C1LM-C2PS, C1LM-C2TL, C1LM-C2/3TA, and C1LM-C2/3TACL. For each condition, the authors evaluated the range of motion and neutral zone across C1 and C2 in all directions.

RESULTS: Compared with the intact spine, each instrumented spine significantly increased in stability at the C1-2 segment. C1LM-C2TL fixation demonstrated similar stability in FE and LB and greater stability in AR than C1LM-C2PS fixation. C1LM-C2/3TA fixation was equivalent in LB and superior in FE to those of C1LM-C2PS and C1LM-C2TL fixation. During AR, the C1LM-C2/3TA-instrumented spine failed to maintain segmental stability. After adding a cross-link, the rotational stability was significantly increased in the C1LM-C2/3TACL-instrumented spine compared with the C1LM-C2/3TA-instrumented spine. Although inferior to C1LM-C2TL fixation, the C1LM-C2/3TACL-instrumented spine showed equivalent rotational stability to the C1LM-C2PS-instrumented spine.

CONCLUSIONS: On the basis of our biomechanical study, C1LM-C2TL and C1LM-C2/3TACL fixation resulted in satisfactory atlantoaxial stabilization compared with C1LM-C2PS. Therefore, the authors believe that the C1LM-C2TL and C1LM-C2/3TACL fixation may serve as alternative procedures when the Goel-Harms technique (C1LM-C2PS) is not feasible due to anatomical constraints.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app