We have located links that may give you full text access.
Correction of estimation bias of predictive equations of energy expenditure based on wrist/waist-mounted accelerometers.
PeerJ 2019
Background: Using wearable inertial sensors to accurately estimate energy expenditure (EE) during an athletic training process is important. Due to the characteristics of inertial sensors, however, the positions in which they are worn can produce signals of different natures. To understand and solve this issue, this study used the heart rate reserve (HRR) as a compensation factor to modify the traditional empirical equation of the accelerometer EE sensor and examine the possibility of improving the estimation of energy expenditure for sensors worn in different positions.
Methods: Indirect calorimetry was used as the criterion measure (CM) to measure the EE of 90 healthy adults on a treadmill (five speeds: 4.8, 6.4, 8.0, 9.7, and 11.3 km/h). The measurement was simultaneously performed with the ActiGraph GT9X-Link (placed on the wrist and waist) with the Polar H10 Heart Rate Monitor.
Results: At the same exercise intensity, the EE measurements of the GT9X on the wrist and waist had significant differences from those of the CM ( p < 0.05). By using multiple regression analysis-utilizing values from vector magnitudes (VM), body weight (BW) and HRR parameters-accuracy of EE estimation was greatly improved compared to traditional equation. Modified models explained a greater proportion of variance (R2 ) (wrist: 0.802; waist: 0.805) and demonstrated a good ICC (wrist: 0.863, waist: 0.889) compared to Freedson's VM3 Combination equation (R2 : wrist: 0.384, waist: 0.783; ICC: wrist: 0.073, waist: 0.868).
Conclusions: The EE estimation equation combining the VM of accelerometer measurements, BW and HRR greatly enhanced the accuracy of EE estimation based on data from accelerometers worn in different positions, particularly from those on the wrist.
Methods: Indirect calorimetry was used as the criterion measure (CM) to measure the EE of 90 healthy adults on a treadmill (five speeds: 4.8, 6.4, 8.0, 9.7, and 11.3 km/h). The measurement was simultaneously performed with the ActiGraph GT9X-Link (placed on the wrist and waist) with the Polar H10 Heart Rate Monitor.
Results: At the same exercise intensity, the EE measurements of the GT9X on the wrist and waist had significant differences from those of the CM ( p < 0.05). By using multiple regression analysis-utilizing values from vector magnitudes (VM), body weight (BW) and HRR parameters-accuracy of EE estimation was greatly improved compared to traditional equation. Modified models explained a greater proportion of variance (R2 ) (wrist: 0.802; waist: 0.805) and demonstrated a good ICC (wrist: 0.863, waist: 0.889) compared to Freedson's VM3 Combination equation (R2 : wrist: 0.384, waist: 0.783; ICC: wrist: 0.073, waist: 0.868).
Conclusions: The EE estimation equation combining the VM of accelerometer measurements, BW and HRR greatly enhanced the accuracy of EE estimation based on data from accelerometers worn in different positions, particularly from those on the wrist.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app