We have located links that may give you full text access.
Pain assessment during eye examination for retinopathy of prematurity screening: Skin conductance versus PIPP-R.
Acta Paediatrica 2019 October 21
AIM: To assess changes in skin conductance during retinopathy of prematurity screening and to study the correlation between the skin conductance and a validated pain scale.
METHODS: Prospective observational study. Fifty-three eye examinations were performed in 32 preterm infant candidates for retinopathy of prematurity screening. Outcome measures were changes in Premature Infant Pain Profile-Revised (PIPP-R) scale and number of skin conductance fluctuations.
RESULTS: There was a significant increase from baseline in the number of skin conductance fluctuations and PIPP-R during the procedure. The maximum value of number of skin conductance fluctuations was 0.64 ± 0.44 peaks/sec, and the maximum value of PIPP-R was 10.8 ± 3.3. A correlation between the skin conductance and PIPP-R was not found at any time during the eye examination. Repeated measures correlation analyses showed only a moderate positive correlation between PIPP-R and number of skin conductance fluctuation values.
CONCLUSION: There were significant changes in both PIPP-R and number of skin conductance fluctuations during retinopathy of prematurity screening, reaffirming that this procedure is painful and stressful. The number of skin conductance fluctuations and PIPP-R are not significantly correlated, which likely reflects that these parameters evaluate different but complementary aspects of neonatal pain responses.
METHODS: Prospective observational study. Fifty-three eye examinations were performed in 32 preterm infant candidates for retinopathy of prematurity screening. Outcome measures were changes in Premature Infant Pain Profile-Revised (PIPP-R) scale and number of skin conductance fluctuations.
RESULTS: There was a significant increase from baseline in the number of skin conductance fluctuations and PIPP-R during the procedure. The maximum value of number of skin conductance fluctuations was 0.64 ± 0.44 peaks/sec, and the maximum value of PIPP-R was 10.8 ± 3.3. A correlation between the skin conductance and PIPP-R was not found at any time during the eye examination. Repeated measures correlation analyses showed only a moderate positive correlation between PIPP-R and number of skin conductance fluctuation values.
CONCLUSION: There were significant changes in both PIPP-R and number of skin conductance fluctuations during retinopathy of prematurity screening, reaffirming that this procedure is painful and stressful. The number of skin conductance fluctuations and PIPP-R are not significantly correlated, which likely reflects that these parameters evaluate different but complementary aspects of neonatal pain responses.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app