OPEN IN READ APP
JOURNAL ARTICLE

Effects of Patent Ductus Arteriosus on Organ Blood Flow in Infants Born Very Preterm: A Prospective Study with Serial Echocardiography

Kai-Hsiang Hsu, Jimmy Nguyen, Stephanie Dekom, Rangasamy Ramanathan, Shahab Noori
Journal of Pediatrics 2019 October 11
31610928

OBJECTIVE: To characterize the effects of a patent ductus arteriosus (PDA) on different organ blood flows in infants born preterm.

STUDY DESIGN: Infants born preterm at ≤30 weeks of gestational age had daily echocardiography and Doppler assessments of middle cerebral artery, celiac artery, superior mesenteric (SMA), and renal arteries (RA) during the first postnatal week. Abnormal organ blood flow was defined as either reverse or absent diastolic flow, abnormally low mean or systolic velocities, or abnormally high pulsatility or resistance index.

RESULTS: Twenty-five infants born very preterm (gestational age 27.0 ± 2.1 weeks) were enrolled. PDA presence at time of measurement increased the risk of abnormal organ blood flows (39% vs 8%, P < .001). Ductal diameter and left atrium-to-aortic root (LA/Ao) ratio correlated positively with resistance index (celiac artery, SMA, RA), and negatively with mean velocity (ductal diameter: SMA, RA; LA/Ao ratio: RA). A PDA >2.0 mm, LA/Ao ratio >1.4, and their combination were associated with 8.0 (95% CI 1.6-39.4)-, 6.7 (1.3-34.7)-, and 38.2 (3.2-455.5)-fold increase in risk of abnormal organ blood flow index, respectively. Abnormal descending aorta flow was detected in only 2% of measurements.

CONCLUSIONS: Ductal size >2.0 mm and LA/Ao >1.4, especially in combination, are associated with a greater risk of abnormal organ blood flows. We suggest that Doppler assessment of the renal and superior mesenteric arteries are more likely to detect systemic hypoperfusion than the descending aorta.

Comments

You need to log in or sign up for an account to be able to comment.

No comments yet, be the first to post one!

Trending on Read

Available on the App Store

Available on the Play Store
Remove bar
Read by QxMD icon Read
31610928
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"