We have located links that may give you full text access.
The role of spleen stiffness using ARFI in predicting esophageal varices in patients with Hepatitis B and C virus-related cirrhosis.
Romanian Journal of Internal Medicine 2019 July 13
INTRODUCTION: Current guidelines recommend that all patients with cirrhosis undergo upper gastrointestinal endoscopy (UGE) screening for esophageal varices (EV). Unfortunately, UGE has a lot of disadvantages, consequently various non-invasive methods of diagnosing EV have been proposed. We evaluated if spleen stiffness measured by Acoustic Radiation Force Impulse (ARFI) is a viable technique in diagnosing EV.
METHODS: We recruited 178 patients with cirrhosis caused by Hepatitis B and C who underwent biochemical tests, abdominal ultrasound, UGE, LS and SS measurements using ARFI elastography. Based on the endoscopic results the patients were divided in 3 groups: without EV, with small EV (<5 mm) and with large EV (>5 mm).
RESULTS: ARFI SS was the only non-invasive parameter associated with the presence of EV (2.7±0.30 vs. 3.4±0.52, p<0.001) and large EV (2.91±0.36 vs. 3.86±0.37, p=0.001) after multivariate logistic regression (p<0.001). ARFI SS for predicting EV showed an AUROC of 0.872 (CI 95%: 0.799-0.944), for a cut-off value of 2.89 m/s: Sensitivity (Se) 91.4% (CI 95%: 81-97%), Specificity (Sp) 67.7% (CI 95%: 51-85%). ARFI SS for diagnosing large EV (>5mm) had better results with an AUROC 0.969 (CI 95%:0.935-0.99), and for a cut-off of 3.30 m/s: Se 96.4% (CI 95%: 82-99.9%), Sp 88.5% (CI 95%: 78-95%).
CONCLUSIONS: SS measured using ARFI is a good method of detecting EV and is an excellent method of diagnosing large EV in patients with virus-related cirrhosis.
METHODS: We recruited 178 patients with cirrhosis caused by Hepatitis B and C who underwent biochemical tests, abdominal ultrasound, UGE, LS and SS measurements using ARFI elastography. Based on the endoscopic results the patients were divided in 3 groups: without EV, with small EV (<5 mm) and with large EV (>5 mm).
RESULTS: ARFI SS was the only non-invasive parameter associated with the presence of EV (2.7±0.30 vs. 3.4±0.52, p<0.001) and large EV (2.91±0.36 vs. 3.86±0.37, p=0.001) after multivariate logistic regression (p<0.001). ARFI SS for predicting EV showed an AUROC of 0.872 (CI 95%: 0.799-0.944), for a cut-off value of 2.89 m/s: Sensitivity (Se) 91.4% (CI 95%: 81-97%), Specificity (Sp) 67.7% (CI 95%: 51-85%). ARFI SS for diagnosing large EV (>5mm) had better results with an AUROC 0.969 (CI 95%:0.935-0.99), and for a cut-off of 3.30 m/s: Se 96.4% (CI 95%: 82-99.9%), Sp 88.5% (CI 95%: 78-95%).
CONCLUSIONS: SS measured using ARFI is a good method of detecting EV and is an excellent method of diagnosing large EV in patients with virus-related cirrhosis.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app