Effect of fixed-setting versus programmable valve on incidence of shunt revision after ventricular shunting for idiopathic normal pressure hydrocephalus.

OBJECTIVE: Although ventricular shunting is an effective therapy for idiopathic normal pressure hydrocephalus (iNPH), the effect of shunt valve type on the incidence of revision surgery is not well defined. To address this issue, shunt revision rates between patients with iNPH receiving a fixed-setting valve (FSV) versus a programmable valve (PV) were compared.

METHODS: Patients with iNPH treated with ventricular shunting between 2001 and 2017 were included for analysis. The incidence of shunt revision was noted and risk factors for revision were identified using a Cox proportional hazards model. Costs associated with admission for ventricular shunt procedures were obtained from the Vizient national database.

RESULTS: There were 348 patients included for analysis, with 98 patients (28.1%) receiving a PV. Shunt revision occurred in 73 patients (21.0%), with 12 patients (3.4%) undergoing multiple revisions. Overall revision rates were lower in patients receiving a PV (13.3% vs 24.0%; p = 0.027), as was the incidence of multiple revisions (0.0% vs 4.8%; p = 0.023). Patients with initial placement of an FSV were also more likely to undergo valve exchange during follow-up (12.4% vs 2.0%; p = 0.003). Patients with a PV were less likely to undergo revision due to persistent symptoms without obstruction (2.0% vs 8.8%; p = 0.031) and distal obstruction (1.0% vs 6.8%; p = 0.030). In a multivariate Cox proportional hazards model, initial placement of a PV was associated with reduced risk of revision due to persistent symptoms without obstruction (OR 0.27, 95% CI 0.04-0.93; p = 0.036). PVs were associated with more frequent shunt series (1.3 vs 0.6; p < 0.001) and head CT scans (3.6 vs 2.7; p = 0.038) during follow-up. There was no significant difference in mean total costs between patients receiving an FSV and a PV ($24,282.50 vs $24,396.90; p = 0.937).

CONCLUSIONS: The authors' results suggest that PVs lead to reduced rates of shunt revision in patients with iNPH, and decreased risk of revision due to persistent symptoms of iNPH, thereby justifying the higher upfront cost of PVs despite similar overall treatment costs between these devices.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app