Preoperative planned distance between the skin surface and the guide rod provides accurate posterior tibial slope in total knee arthroplasty.
Archives of Orthopaedic and Trauma Surgery 2019 May 28
BACKGROUND: Although sagittal tibial alignment in total knee arthroplasty (TKA) is important, no landmark exists to achieve reproducible slope. It is theoretically demonstrated that the preoperative planned distance between the skin surface and the rod can be a useful guide for the tibial slope in the previous imaging study. We conducted this retrospective study to confirm whether the results of the study are repeatable in an intra-operative situation.
METHODS: Fifty-five consecutive TKAs using the distance from the extramedullary cutting guide rod to the skin surface as a reference guide for the tibial slope were performed and tibial component positioning was compared with 55 knees performed using the accelerometer-based portable navigation. The tibial component alignment was evaluated with a computed tomography (CT)-based three-dimensional (3D) software.
RESULTS: The absolute mean deviation from the targeted slope in the proposed method was significantly smaller than the portable navigation (1.0° and 1.7°, respectively, p = 0.0025). The outlier rate beyond 3° was 0% in the proposed technique (16.4% in the portable navigation, p = 0.0014).
CONCLUSIONS: The preoperative planned distance between the skin surface and the guide rod is a useful technique to provide accurate posterior tibial slope in TKA.
METHODS: Fifty-five consecutive TKAs using the distance from the extramedullary cutting guide rod to the skin surface as a reference guide for the tibial slope were performed and tibial component positioning was compared with 55 knees performed using the accelerometer-based portable navigation. The tibial component alignment was evaluated with a computed tomography (CT)-based three-dimensional (3D) software.
RESULTS: The absolute mean deviation from the targeted slope in the proposed method was significantly smaller than the portable navigation (1.0° and 1.7°, respectively, p = 0.0025). The outlier rate beyond 3° was 0% in the proposed technique (16.4% in the portable navigation, p = 0.0014).
CONCLUSIONS: The preoperative planned distance between the skin surface and the guide rod is a useful technique to provide accurate posterior tibial slope in TKA.
Full text links
Related Resources
Trending Papers
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app