Effect of Implementing Quantitative Blood Loss Assessment at the Time of Delivery.
American Journal of Perinatology 2019 November
OBJECTIVE: To evaluate the ability of estimated blood loss (EBL) and quantitative blood loss (qBL) to predict need for blood transfusion in women with postpartum hemorrhage (PPH).
STUDY DESIGN: This is a retrospective chart review that identified women with PPH (>1,000 mL for vaginal or cesarean delivery) between September 2014 and August 2015, reported by EBL ( n = 92), and October 2015 and September 2016, reported by qBL ( n = 374). The primary metric was the area under the receiver-operating characteristic curve for blood transfusion.
RESULTS: The rate of PPH by EBL and qBL was 2.8 and 10.8%, respectively ( p < 0.01). The rate of transfusion for women meeting criteria for PPH by EBL and QBL were 2% (66/3,307) and 2.7% (93/3,453), respectively ( p = 0.06). Postpartum transfusion was predicted by an EBL of 1,450 mL with AUC 0.826 and qBL 1,519 mL with AUC 0.764, for all modes of delivery. Postpartum vital signs and change in pre- and postdelivery hematocrit were poor predictors for transfusion.
CONCLUSION: The rates of PPH increased with the implementation of qBL. Overall, qBL did not perform better than EBL in predicting the need for blood transfusion.
STUDY DESIGN: This is a retrospective chart review that identified women with PPH (>1,000 mL for vaginal or cesarean delivery) between September 2014 and August 2015, reported by EBL ( n = 92), and October 2015 and September 2016, reported by qBL ( n = 374). The primary metric was the area under the receiver-operating characteristic curve for blood transfusion.
RESULTS: The rate of PPH by EBL and qBL was 2.8 and 10.8%, respectively ( p < 0.01). The rate of transfusion for women meeting criteria for PPH by EBL and QBL were 2% (66/3,307) and 2.7% (93/3,453), respectively ( p = 0.06). Postpartum transfusion was predicted by an EBL of 1,450 mL with AUC 0.826 and qBL 1,519 mL with AUC 0.764, for all modes of delivery. Postpartum vital signs and change in pre- and postdelivery hematocrit were poor predictors for transfusion.
CONCLUSION: The rates of PPH increased with the implementation of qBL. Overall, qBL did not perform better than EBL in predicting the need for blood transfusion.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app