We have located links that may give you full text access.
Extended drip infusion of peripheral parental nutrition containing amino acids might be associated with Bacillus cereus bloodstream infection.
American Journal of Infection Control 2019 September
In some Japanese hospitals, patients using infusion bags for parenteral nutrition containing amino acids have developed Bacillus cereus bloodstream infections. We considered that proliferation of contaminated B cereus in the bag during prolonged drip infusion might be one of the causes of infection. This study indicated that 8 h is the maximum appropriate drip infusion time for peripheral parental nutrition containing amino acids to prevent B cereus bloodstream infections.