Cardiac T2* magnetic resonance analysis of membranous interventricular septum in assessment of cardiac iron overload in pediatric thalassemia patients: A pilot study.
Indian Journal of Radiology & Imaging 2019 January
Background: Cardiac iron deposition in transfusion-dependent thalassemia patients is patchy in distribution.
Purpose: The purpose of this study is to assess the correlation between T2* matrices of membranous interventricular septum (MIVS) and T2* values of muscular interventricular septum (IVS) on magnetic resonance imaging (MRI) and to evaluate the relationship of myocardial T2* at these two locations with MRI-estimated liver iron concentrations (LIC) and electrocardiographic (ECG) parameters.
Material and Methods: MRI of heart and liver was performed in 16 consecutive pediatric patients of transfusion-dependent thalassemia major to calculate liver iron concentration and T2* time of membranous and muscular IVS. ECG parameters of these patients were charted and correlated with MRI parameters.
Results: No significant correlation between T2* values of muscular IVS and MIVS was observed. Mean T2* of MIVS (9.8 ms) was significantly lower than that of muscular IVS (26.9 ms). T2* of MIVS correlated strongly with LIC where as a weak correlation was observed between T2* of IVS and LIC. Significantly higher mean QTc (corrected QT interval) value (439.86 ms) was seen in patients with T2* IVS <20 ms.
Conclusion: Addition of T2* analysis of MIVS to the existing MRI protocol, consisting of muscular IVS analysis, may offer a more sensitive estimation of cardiac iron overload.
Purpose: The purpose of this study is to assess the correlation between T2* matrices of membranous interventricular septum (MIVS) and T2* values of muscular interventricular septum (IVS) on magnetic resonance imaging (MRI) and to evaluate the relationship of myocardial T2* at these two locations with MRI-estimated liver iron concentrations (LIC) and electrocardiographic (ECG) parameters.
Material and Methods: MRI of heart and liver was performed in 16 consecutive pediatric patients of transfusion-dependent thalassemia major to calculate liver iron concentration and T2* time of membranous and muscular IVS. ECG parameters of these patients were charted and correlated with MRI parameters.
Results: No significant correlation between T2* values of muscular IVS and MIVS was observed. Mean T2* of MIVS (9.8 ms) was significantly lower than that of muscular IVS (26.9 ms). T2* of MIVS correlated strongly with LIC where as a weak correlation was observed between T2* of IVS and LIC. Significantly higher mean QTc (corrected QT interval) value (439.86 ms) was seen in patients with T2* IVS <20 ms.
Conclusion: Addition of T2* analysis of MIVS to the existing MRI protocol, consisting of muscular IVS analysis, may offer a more sensitive estimation of cardiac iron overload.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app