We have located links that may give you full text access.
Detection of aseptic loosening in total knee replacements: a systematic review and meta-analysis.
Skeletal Radiology 2019 October
OBJECTIVE: The aim of this study was to compare the diagnostic accuracy of nuclear imaging modalities in the detection of aseptic loosening of total knee arthroplasty (TKA).
MATERIALS AND METHODS: MEDLINE, EMBASE, and the Cochrane Database of Systematic Reviews were searched from database inception to December 2018 in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Included studies compared the results of a single imaging modality against an appropriate reference standard of prosthetic TKA loosening, with sufficient information to determine either sensitivity and/or specificity. The methodological quality of the studies was assessed using the QUADAS-2 tool.
RESULTS: The search strategy identified 572 abstracts. Of these, 12 studies comprising 401 patients across four modalities (bone scintigraphy, 18F-FDG-PET, SPECT/CT arthrogram, radionuclide arthrogram) met the inclusion criteria. All included studies used operative findings, a period of clinical or radiographic observation or both as a reference standard for aseptic loosening. Sixteen comparisons with the reference standards were extracted. All studies were at risk of bias across patient selection, the index test, reference standard, and flow and timing of patients. The most accurate test for diagnosis of aseptic loosening in TKA was SPECT/CT arthrography demonstrated by the summary receiver operating characteristic curve.
CONCLUSIONS: The best available evidence suggests the most accurate modality for the detection of aseptic loosening in TKA is SPECT/CT arthrography. However, the available evidence has a high risk of bias, and total number of patients studied for each modality is small so further studies are warranted.
MATERIALS AND METHODS: MEDLINE, EMBASE, and the Cochrane Database of Systematic Reviews were searched from database inception to December 2018 in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Included studies compared the results of a single imaging modality against an appropriate reference standard of prosthetic TKA loosening, with sufficient information to determine either sensitivity and/or specificity. The methodological quality of the studies was assessed using the QUADAS-2 tool.
RESULTS: The search strategy identified 572 abstracts. Of these, 12 studies comprising 401 patients across four modalities (bone scintigraphy, 18F-FDG-PET, SPECT/CT arthrogram, radionuclide arthrogram) met the inclusion criteria. All included studies used operative findings, a period of clinical or radiographic observation or both as a reference standard for aseptic loosening. Sixteen comparisons with the reference standards were extracted. All studies were at risk of bias across patient selection, the index test, reference standard, and flow and timing of patients. The most accurate test for diagnosis of aseptic loosening in TKA was SPECT/CT arthrography demonstrated by the summary receiver operating characteristic curve.
CONCLUSIONS: The best available evidence suggests the most accurate modality for the detection of aseptic loosening in TKA is SPECT/CT arthrography. However, the available evidence has a high risk of bias, and total number of patients studied for each modality is small so further studies are warranted.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app