We have located links that may give you full text access.
Whole blood platelet aggregation determined by the ROTEM platelet equipment; reference intervals and stability.
Platelets 2019 April 2
Point of care testing of residual effect of antiplatelet therapy in trauma patients or during major surgery may result in improved clinical management of significant bleeding. We included 121 healthy individuals (57 females and 64 males, aged 22-65 years) in order to establish reference intervals for platelet aggregation induced by adenosine diphosphate (ADPTEM, 10 µM), arachidonic acid (ARATEM, 0.42 mM) and thrombin activating peptide (TRAPTEM, 36 µM) employing the ROTEM platelet module. Further, the impact of citrate (3.2%) and hirudin (>15 µg/ml) as anticoagulants was evaluated. Finally, we investigated assay stability (15, 30, 60, and 120 min after blood sampling) (n = 8) and between-day variation (n = 5). We report reference intervals for 121 healthy individuals and reference intervals by gender. We observed significantly higher platelet aggregation in females than in males (all P-values < 0.05). No correlation between age and platelet aggregation was observed, except for the parameter TRAPTEM amplitude (A6), in which a decline in A6 was observed with increasing age (P = 0.03). We observed significantly lower levels of platelet aggregation in citrate tubes than in hirudin tubes (all P-values < 0.05), except from TRAPTEM maximum slope, where no significant difference was observed (P = 0.40). The stability was acceptable (≤20% deviation) for up to 120 min for ARATEM in citrate tubes, and up to 60 min for the ADPTEM and TRAPTEM assays in citrate tubes. In hirudin tubes we found ADPTEM and ARATEM assays to be stable for 60 min, while the stability of TRAPTEM in hirudin tubes was found to be stable for 30 min. Using citrate tubes, the between-day variation (mean coefficient of variation, CV) was 19-20% for ADPTEM, 19-26% for TRAPTEM, and 10% for ARATEM, whereas the mean CV was 11-13% for all three assays in hirudin tubes. In conclusion, we established combined and gender-specific reference intervals for three platelet aggregation assays in both citrate- and hirudin tubes. In citrate tubes, the stability of the ROTEM platelet assays was 60-120 min, while the stability in hirudin tubes was 30-60 min. The between-day variation was lowest for samples obtained in hirudin tubes.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app