Analytical simulator of proton radiography and tomography for different detector configurations.
Physica Medica : PM 2019 March
PURPOSE: An analytical simulator of ion Radiography (iRad) and Computed Tomography (iCT) for protons is proposed to serve as imaging benchmark for different detector configurations.
METHODS: The analytical simulator is applied to an anthropomorphic phantom and provides iRad and iCT benchmarks. Proton trajectories are traced relying on the Most Likely Path (MLP) algorithm. To simulate the proton trajectories the Multiple Coulomb Scattering (MCS) model embedded in the MLP algorithm is extended to non-uniform water equivalent materials according to variable substitution in the well-known statistical description in uniform water. The proton trajectories are instead estimated relying on the typical assumption of uniform water, thus causing intrinsic inaccuracies of the MLP algorithm. In this work the analytical simulator is used to explore and firstly compare the imaging performances of list-mode and integration-mode detector configurations with proton pencil beam scanning.
RESULTS: The intrinsic inaccuracies of the MLP algorithm affect the imaging performances of list-mode detector configuration, which nevertheless remains superior to integration-mode detector configuration for iCTs. For relatively higher proton statistics, comparable or better imaging performances are offered by integration-mode detector configuration for iRads (upto 29.2% of WET difference). Uncertainties of proton trajectories due to beam spot size are shown to compromise the imaging performances of integration-mode detector configuration, but also to affect the accuracy of the MLP algorithm for list-mode detector configuration.
CONCLUSIONS: Based on MCS model in non-uniform water equivalent materials, the proposed simulation environment can serve for development and testing of dedicated imaging methodologies prior to and in combination with realistic Monte Carlo simulations.
METHODS: The analytical simulator is applied to an anthropomorphic phantom and provides iRad and iCT benchmarks. Proton trajectories are traced relying on the Most Likely Path (MLP) algorithm. To simulate the proton trajectories the Multiple Coulomb Scattering (MCS) model embedded in the MLP algorithm is extended to non-uniform water equivalent materials according to variable substitution in the well-known statistical description in uniform water. The proton trajectories are instead estimated relying on the typical assumption of uniform water, thus causing intrinsic inaccuracies of the MLP algorithm. In this work the analytical simulator is used to explore and firstly compare the imaging performances of list-mode and integration-mode detector configurations with proton pencil beam scanning.
RESULTS: The intrinsic inaccuracies of the MLP algorithm affect the imaging performances of list-mode detector configuration, which nevertheless remains superior to integration-mode detector configuration for iCTs. For relatively higher proton statistics, comparable or better imaging performances are offered by integration-mode detector configuration for iRads (upto 29.2% of WET difference). Uncertainties of proton trajectories due to beam spot size are shown to compromise the imaging performances of integration-mode detector configuration, but also to affect the accuracy of the MLP algorithm for list-mode detector configuration.
CONCLUSIONS: Based on MCS model in non-uniform water equivalent materials, the proposed simulation environment can serve for development and testing of dedicated imaging methodologies prior to and in combination with realistic Monte Carlo simulations.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app