STUDY OBJECTIVE: We examine the utility of emergency department (ED) ultrasonography in treatment of skin and soft tissue infections.
METHODS: We enrolled ED patients with skin and soft tissue infections and surveyed clinicians in regard to their pre-ultrasonography certainty about the presence or absence of an abscess, their planned management, post-ultrasonography findings, and actual management. We determined sensitivity and specificity of ultrasonography and clinical evaluation, and assessed appropriateness of management changes based on initial clinical assessment and outcomes through 1-week follow-up.
RESULTS: Among 1,216 patients, clinicians were uncertain of abscess presence in 105 cases (8.6%) and certain for 1,111 cases (91.4%). Based on surgical exploration and follow-up through 1 week, sensitivity and specificity for abscess detection by clinical evaluation were 90.3% and 97.7%, and by ultrasonography were 94.0% and 94.1%, respectively. Among 1,111 cases for which the clinician was certain, sensitivity and specificity of clinical evaluation were 96.6% and 97.3% compared with ultrasonographic evaluation sensitivity and specificity of 95.7% and 96.2%, respectively. Of 105 uncertain cases, sensitivity and specificity of ultrasonography were 68.5% and 80.4%. Ultrasonography changed management in 13 of 1,111 certain cases (1.2%), appropriately in 10 of 13 (76.9%) and inappropriately in 3 of 13 (23.1%). Of 105 uncertain cases, ultrasonography changed management in 25 (23.8%), appropriately in 21 of 25 (84.0%) and inappropriately in 4 of 25 (16.0%).
CONCLUSION: Ultrasonography rarely changed management when clinicians were certain about the presence or absence of an abscess. When they were uncertain, ultrasonography changed drainage decisions in approximately one quarter of cases, of which most (84%) were appropriate.
METHODS: We enrolled ED patients with skin and soft tissue infections and surveyed clinicians in regard to their pre-ultrasonography certainty about the presence or absence of an abscess, their planned management, post-ultrasonography findings, and actual management. We determined sensitivity and specificity of ultrasonography and clinical evaluation, and assessed appropriateness of management changes based on initial clinical assessment and outcomes through 1-week follow-up.
RESULTS: Among 1,216 patients, clinicians were uncertain of abscess presence in 105 cases (8.6%) and certain for 1,111 cases (91.4%). Based on surgical exploration and follow-up through 1 week, sensitivity and specificity for abscess detection by clinical evaluation were 90.3% and 97.7%, and by ultrasonography were 94.0% and 94.1%, respectively. Among 1,111 cases for which the clinician was certain, sensitivity and specificity of clinical evaluation were 96.6% and 97.3% compared with ultrasonographic evaluation sensitivity and specificity of 95.7% and 96.2%, respectively. Of 105 uncertain cases, sensitivity and specificity of ultrasonography were 68.5% and 80.4%. Ultrasonography changed management in 13 of 1,111 certain cases (1.2%), appropriately in 10 of 13 (76.9%) and inappropriately in 3 of 13 (23.1%). Of 105 uncertain cases, ultrasonography changed management in 25 (23.8%), appropriately in 21 of 25 (84.0%) and inappropriately in 4 of 25 (16.0%).
CONCLUSION: Ultrasonography rarely changed management when clinicians were certain about the presence or absence of an abscess. When they were uncertain, ultrasonography changed drainage decisions in approximately one quarter of cases, of which most (84%) were appropriate.
Full text links
Trending Papers
Cardiovascular Disease in Diabetes and Chronic Kidney Disease.Journal of Clinical Medicine 2023 November 9
Monitoring Macro- and Microcirculation in the Critically Ill: A Narrative Review.Avicenna Journal of Medicine 2023 July
Euglycemic Ketoacidosis in Two Patients Without Diabetes After Introduction of Sodium-Glucose Cotransporter 2 Inhibitor for Heart Failure With Reduced Ejection Fraction.Diabetes Care 2023 November 22
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app