Ultra-Low-Dose Neck CT With Low-Dose Contrast Material for Preoperative Staging of Thyroid Cancer: Image Quality and Diagnostic Performance.
AJR. American Journal of Roentgenology 2019 April
OBJECTIVE: Although CT has been used as a complementary diagnostic method for the preoperative diagnosis of thyroid cancer, it has the shortcomings of substantial radiation exposure and the use of contrast material (CM). The purpose of this article is to evaluate the image quality and diagnostic performance of 70-kVp thyroid CT with low volumes of CM versus conventional 120-kVp thyroid CT protocol.
MATERIALS AND METHODS: Eighty patients referred for preoperative thyroid CT were randomly divided into two groups (group A: 40 patients, 70 kVp, 60 mL of CM; group B: 40 patients, 120 kVp, 100 mL of CM). Quantitative and qualitative image quality and radiation doses for the two groups were compared using the Mann-Whitney U and chi-square tests. Degrees of agreement between preoperative CT staging and pathologic results were evaluated and compared using the Wald statistic.
RESULTS: Calculated signal-to-noise ratios of different anatomic structures, calculated contrast-to-noise ratios, overall image quality, subjective noise, and streak artifacts were not significantly different between the two groups (all p > 0.05), and neither were the accuracies of preoperative CT staging (all p > 0.05). The estimated effective doses were significantly lower in group A (mean [± SD], 0.52 ± 0.14 mSv in group A and 2.28 ± 0.29 mSv in group B; p < 0.001).
CONCLUSION: Ultra-low-dose 70-kVp CT with a low volume of CM provides sufficient image quality for preoperative staging of thyroid cancer and substantially reduces the radiation dose compared with standard 120-kVp CT.
MATERIALS AND METHODS: Eighty patients referred for preoperative thyroid CT were randomly divided into two groups (group A: 40 patients, 70 kVp, 60 mL of CM; group B: 40 patients, 120 kVp, 100 mL of CM). Quantitative and qualitative image quality and radiation doses for the two groups were compared using the Mann-Whitney U and chi-square tests. Degrees of agreement between preoperative CT staging and pathologic results were evaluated and compared using the Wald statistic.
RESULTS: Calculated signal-to-noise ratios of different anatomic structures, calculated contrast-to-noise ratios, overall image quality, subjective noise, and streak artifacts were not significantly different between the two groups (all p > 0.05), and neither were the accuracies of preoperative CT staging (all p > 0.05). The estimated effective doses were significantly lower in group A (mean [± SD], 0.52 ± 0.14 mSv in group A and 2.28 ± 0.29 mSv in group B; p < 0.001).
CONCLUSION: Ultra-low-dose 70-kVp CT with a low volume of CM provides sufficient image quality for preoperative staging of thyroid cancer and substantially reduces the radiation dose compared with standard 120-kVp CT.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
The Effect of Albumin Administration in Critically Ill Patients: A Retrospective Single-Center Analysis.Critical Care Medicine 2024 Februrary 8
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app