Axis screws: results and complications of a large case series.
Revista da Associação Médica Brasileira 2019 Februrary
OBJECTIVE: To present the surgical results of patients who underwent axis screw instrumentation, discussing surgical nuances and complications of the techniques used.
METHODS: Retrospective case-series evaluation of patients who underwent spinal surgery with axis instrumentation using screws.
RESULTS: Sixty-five patients were included in this study. The most common cause of mechanical instability was spinal cord trauma involving the axis (36 patients - 55.4%), followed by congenital craniocervical malformation (12 patients - 18.5%). Thirty-seven (57%) patients required concomitant C1 fusion. Bilateral axis fixation was performed in almost all cases. Twenty-three patients (35.4%) underwent bilateral laminar screws fixation; pars screws were used in twenty-two patients (33.8%), and pedicular screws were used isolated in only three patients (4.6%). In fourteen patients (21.5%), we performed a hybrid construction. There was no neurological worsening nor vertebral artery injury in this series.
CONCLUSION: Axis screw instrumentation proved to be a safe and efficient method for cervical stabilization. Laminar and pars screws were the most commonly used.
METHODS: Retrospective case-series evaluation of patients who underwent spinal surgery with axis instrumentation using screws.
RESULTS: Sixty-five patients were included in this study. The most common cause of mechanical instability was spinal cord trauma involving the axis (36 patients - 55.4%), followed by congenital craniocervical malformation (12 patients - 18.5%). Thirty-seven (57%) patients required concomitant C1 fusion. Bilateral axis fixation was performed in almost all cases. Twenty-three patients (35.4%) underwent bilateral laminar screws fixation; pars screws were used in twenty-two patients (33.8%), and pedicular screws were used isolated in only three patients (4.6%). In fourteen patients (21.5%), we performed a hybrid construction. There was no neurological worsening nor vertebral artery injury in this series.
CONCLUSION: Axis screw instrumentation proved to be a safe and efficient method for cervical stabilization. Laminar and pars screws were the most commonly used.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app