We have located links that may give you full text access.
Multi-electrode sequential versus single electrode stimulation to elicit the stapedial reflex during cochlear implantation: Correlation with maximum comfort level.
OBJECTIVES: To assess whether electrical stimulation sequentially delivered through 4 electrodes located in different cochlear areas may elicit the stapedial reflex at lower levels compared to single electrode stimulation and to correlate the sequentially obtained values with the maximum comfort level (C-level).
PATIENTS AND METHODS: A retrospective study was performed on 35 post-verbal adult patients (age 19-80 years) consecutively implanted in 2 cochlear implant centers, evaluating the level of stimulation (pulse width) necessary to electrically evoke the stapedial reflex with two different stimulation modalities: single electrode versus sequential 4 electrode stimulation. Threshold values were compared with C-level obtained at activation.
RESULTS: The average differences of pulse width and C-level were significantly smaller (P<0.0001) when the stapedial reflex was obtained with the sequential stimulation modality and reached statistical significance for every single electrode (P<0.0001).
CONCLUSIONS: Stapedial reflex thresholds obtained with sequential stimulation through 4 different electrodes significantly correlate to the C-level obtained at the first setting and may be helpful in defining the upper limit of the dynamic field during initial CI mapping.
PATIENTS AND METHODS: A retrospective study was performed on 35 post-verbal adult patients (age 19-80 years) consecutively implanted in 2 cochlear implant centers, evaluating the level of stimulation (pulse width) necessary to electrically evoke the stapedial reflex with two different stimulation modalities: single electrode versus sequential 4 electrode stimulation. Threshold values were compared with C-level obtained at activation.
RESULTS: The average differences of pulse width and C-level were significantly smaller (P<0.0001) when the stapedial reflex was obtained with the sequential stimulation modality and reached statistical significance for every single electrode (P<0.0001).
CONCLUSIONS: Stapedial reflex thresholds obtained with sequential stimulation through 4 different electrodes significantly correlate to the C-level obtained at the first setting and may be helpful in defining the upper limit of the dynamic field during initial CI mapping.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app