Add like
Add dislike
Add to saved papers

A novel biometric approach to estimating tidal volume.

BACKGROUND: Low tidal volume ventilation (LTVV) of 4-8 mL/kg of ideal body weight (IBW) reduces mortality in patients with acute respiratory distress syndrome, and, more recently, it has been recommended as the default therapy for all controlled ventilation. However, adherence to LTVV is poor. Barriers to adherence include not having height measurements taken or IBW calculated during admission. The aim of our project was to develop and validate a simple one step biometric measuring tool to directly estimate tidal volume (VT ) in ventilated patients based on their demispan.

OBJECTIVES: To validate our novel biometric approach for the estimation of VT in mechanically ventilated patients by demonstrating its accuracy as a simple reliable alternative to IBW derived from measured height.

DESIGN AND SETTING: A simple computer program was written based on regression equations for demispan, height and IBW which used simple substitution to produce a vector graphic scale with markings in millilitres of 6 mL/kg IBW VT printed onto a paper tape. We performed an observational validation study on ventilated patients after cardiac surgery comparing the VT derived from demispan measurements using our tape with the VT based on IBW calculated from pre-operative vertical height.

MAIN OUTCOME MEASURE: We compared compliance with a target VT ≤ 6.5 mL/kg for VT derived using our demispan method and with VT based on IBW calculated from vertical height.

RESULTS: Eighty-two patients were studied. The mean age was 65.7 years (SD, 11.4) and 61 patients (74%) were male. Mean height was 170.4 cm (SD, 9.5) and mean body mass index for the group was 28.6 kg/m2 (SD, 5.5). The VT based on 6 mL/kg IBW estimated by traditional height method and using our biometric tape method correlated well (r = 0.8) and was not statistically different, with a mean difference of -7.5 mL (SEM, 8.8). Bland-Altman plot showed 95% limits of agreement from -64 mL to 79 mL around the mean difference of 7.5 mL, with 4 points (4.9%) outside the limits of agreement. Fifty-one of the initial VT (62%) were compliant, with a target of ≤ 6.5 mL/kg IBW using volumes determined from measured height, while 66 of the tape volumes (80%) would have been compliant at a target of ≤ 6.5 mL/kg IBW.

CONCLUSION: Estimating VT using of our biometric one step approach based on demispan correlates well with VT derived from vertical height. The simplicity of its use and accuracy could lead to improved adherence in a large cohort of patients who currently do not receive the recommended VT restriction.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app