Evaluation of a Computerized Insulin Dosing Tool for the Treatment of Diabetic Ketoacidosis.
Journal of Pharmacy Practice 2019 March 11
PURPOSE:: Computerized insulin dosing tools (CIDT) have been shown to improve the care of critically ill patients with hyperglycemia. Application of a CIDT in addition to a diabetic ketoacidosis (DKA) order set for the treatment of DKA has not been evaluated. Our goal was to determine the effects the CIDT would have on the treatment of a patient with DKA.
METHODS:: In this retrospective, pre-post chart review, a provider-driven insulin dosing strategy (pregroup) was compared to the CIDT (postgroup) with 24-hour pharmacist monitoring. The CIDT utilized an equation that incorporated a patient's most recent blood glucose (BG) value and recommended a rate of insulin (units/hour) every hour.
RESULTS:: All baseline characterizes were similar between the 2 groups. There were no significant differences in average time to anion gap closure (≤ 12 mEq/L) or intensive care unit length of stay between the pregroup and postgroup (12.5 [6] hours vs 10.5 [7] hours, P = 0.235; 40.6 [24] hours vs 40.8 [24] hours, P = 0.945). Although not statistically significant, 17 hypoglycemic events (BG < 70 mg/dL) occurred in the pregroup with 4 being severe (BG < 50 mg/dL) while 5 hypoglycemic events occurred in the postgroup, none of which were severe.
CONCLUSION:: This study suggests, when compared to a provider-driven insulin dosing strategy, the CIDT with 24-hour pharmacist monitoring is efficacious and safe for treatment of patients with a primary diagnosis of DKA.
METHODS:: In this retrospective, pre-post chart review, a provider-driven insulin dosing strategy (pregroup) was compared to the CIDT (postgroup) with 24-hour pharmacist monitoring. The CIDT utilized an equation that incorporated a patient's most recent blood glucose (BG) value and recommended a rate of insulin (units/hour) every hour.
RESULTS:: All baseline characterizes were similar between the 2 groups. There were no significant differences in average time to anion gap closure (≤ 12 mEq/L) or intensive care unit length of stay between the pregroup and postgroup (12.5 [6] hours vs 10.5 [7] hours, P = 0.235; 40.6 [24] hours vs 40.8 [24] hours, P = 0.945). Although not statistically significant, 17 hypoglycemic events (BG < 70 mg/dL) occurred in the pregroup with 4 being severe (BG < 50 mg/dL) while 5 hypoglycemic events occurred in the postgroup, none of which were severe.
CONCLUSION:: This study suggests, when compared to a provider-driven insulin dosing strategy, the CIDT with 24-hour pharmacist monitoring is efficacious and safe for treatment of patients with a primary diagnosis of DKA.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app