Radiation exposure during videofluoroscopic swallowing studies in young children.
International Journal of Pediatric Otorhinolaryngology 2019 Februrary 26
OBJECTIVES: Swallowing difficulties are best assessed by videofluoroscopic swallowing studies (VFSS). However, limiting radiation exposure is important, especially in young children. The purpose was to evaluate radiation dose in young children during VFSS, and to investigate factors associated with it.
METHODS: Children with swallowing difficulty who underwent VFSS from February 2012 to July 2014 were recruited. Dose area product (DAP) and screening time were offered by the fluoroscopy machine, and effective dose was calculated from the DAP using a conversion coefficient published by the National Radiological Protection Board (NRPB-R262). The age, gender, height, weight, body mass index (BMI), body surface area (BSA), underlying disease of the subject children, and results of VFSS were investigated.
RESULTS: In 89 children (mean age 1.57 ± 2.17, 55 boys and 34 girls), mean effective dose was 0.29 ± 0.20 mSv, mean DAP was 2.41 ± 1.65 Gy cm2 , and mean screening time was 2.24 ± 0.99 min. The effective dose correlated with the screening time (r = 0.598, p < 0.001), age (r = 0.210, p = 0.049), height (r = 0.521, p < 0.001), weight (r = 0.461, p < 0.001), and BSA (r = 0.493, p < 0.001). There was no such correlation with gender, BMI, underlying disease, or the results of VFSS.
CONCLUSIONS: The effective dose during VFSS (0.29 mSv) in young children, which is affected by screening time, age, and body size, is considerably lower than the pediatric radiation exposure limit of 1 mSv per year. However more than 4 VFSS annually would exceed this limit. Our findings will help physicians to reduce the radiation exposure and provide a useful references for future pediatric VFSS guidelines.
METHODS: Children with swallowing difficulty who underwent VFSS from February 2012 to July 2014 were recruited. Dose area product (DAP) and screening time were offered by the fluoroscopy machine, and effective dose was calculated from the DAP using a conversion coefficient published by the National Radiological Protection Board (NRPB-R262). The age, gender, height, weight, body mass index (BMI), body surface area (BSA), underlying disease of the subject children, and results of VFSS were investigated.
RESULTS: In 89 children (mean age 1.57 ± 2.17, 55 boys and 34 girls), mean effective dose was 0.29 ± 0.20 mSv, mean DAP was 2.41 ± 1.65 Gy cm2 , and mean screening time was 2.24 ± 0.99 min. The effective dose correlated with the screening time (r = 0.598, p < 0.001), age (r = 0.210, p = 0.049), height (r = 0.521, p < 0.001), weight (r = 0.461, p < 0.001), and BSA (r = 0.493, p < 0.001). There was no such correlation with gender, BMI, underlying disease, or the results of VFSS.
CONCLUSIONS: The effective dose during VFSS (0.29 mSv) in young children, which is affected by screening time, age, and body size, is considerably lower than the pediatric radiation exposure limit of 1 mSv per year. However more than 4 VFSS annually would exceed this limit. Our findings will help physicians to reduce the radiation exposure and provide a useful references for future pediatric VFSS guidelines.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app