We have located links that may give you full text access.
JOURNAL ARTICLE
MULTICENTER STUDY
Third Annual Pediatric Interagency Registry for Mechanical Circulatory Support (Pedimacs) Report: Preimplant Characteristics and Outcomes.
Annals of Thoracic Surgery 2019 April
BACKGROUND: The influence of ventricular assist device (VAD) use in the care of children with end-stage heart failure is growing rapidly through increasing numbers, new devices, expanding indications, and improving outcomes. Pediatric Interagency Registry for Mechanical Circulatory Support (Pedimacs), a National Institutes of Health-sponsored United States database, provides a platform to understand this emerging population.
METHODS: Between September 19, 2012, and December 31, 2017, 30 hospitals implanted 508 devices in 423 patients aged younger than 19 years. This past year was one of evolution for the database as its management was transitioned to The Society of Thoracic Surgery; therefore, this report does not include data from institutions not under contract by August 1, 2018.
RESULTS: Of the 423 patients, the diagnosis was cardiomyopathy in 261 (62%), myocarditis in 48 (11%), other in 28 (7%), and congenital heart disease (CHD) in 86 (20%), with 52 of these patients having single-ventricle physiology. The two most common support strategies included left VAD in 342 (81%) and biventricular assist device in 64 (15%). Positive outcome (alive on device or bridge to transplantation/recovery) was 80% at 6 months (overall mortality of 20%). The patient cohort for implantable continuous-flow (IC) pumps (n = 197; age at implant, 13.4 ± 3.8 years; 19% Interagency Registry for Mechanically Assisted Circulatory Support [Intermacs] profile 1, 21% intubated at implant, and 12% with CHD) was significantly different from the paracorporeal continuous-flow (PC) pump cohort (n = 79; age, 3.9 ± 5.2 years; 49% Intermacs profile 1, 86% intubated at implant, and 38% with CHD) and the paracorporeal pulsatile (PP) pump cohort (n = 121; age, 3.3 ± 3.9 years; 41% Intermacs profile 1, 77% intubated at implant, and 21% with CHD). Consistent with their cohort composition, device type positive outcomes at 6 months were PC, 63%; PP, 77%; and IC, 92%. Parametric hazard modeling showed an early hazard for death was associated with Intermacs profile 1, biventricular assist device, percutaneous devices, PC devices, small-volume institutions, low age, and low weight, whereas a constant hazard was associated with intubation and liver dysfunction at time of implant.
CONCLUSIONS: IC VADs are the most common VAD type placed in children. The positive outcomes for the IC VADs exceed 90% at 6 months, which may represent our field's maturation in both patient selection and timing of implantation. The PP/PC devices are currently limited to supporting our most challenging patients, those weighing less than 20 kg and those with CHD. The introduction of new devices and our communities' commitment to shared learning and improvement will lead to more pediatric lives saved by VAD support and will also focus on improving the quality of life of children supported with VADs.
METHODS: Between September 19, 2012, and December 31, 2017, 30 hospitals implanted 508 devices in 423 patients aged younger than 19 years. This past year was one of evolution for the database as its management was transitioned to The Society of Thoracic Surgery; therefore, this report does not include data from institutions not under contract by August 1, 2018.
RESULTS: Of the 423 patients, the diagnosis was cardiomyopathy in 261 (62%), myocarditis in 48 (11%), other in 28 (7%), and congenital heart disease (CHD) in 86 (20%), with 52 of these patients having single-ventricle physiology. The two most common support strategies included left VAD in 342 (81%) and biventricular assist device in 64 (15%). Positive outcome (alive on device or bridge to transplantation/recovery) was 80% at 6 months (overall mortality of 20%). The patient cohort for implantable continuous-flow (IC) pumps (n = 197; age at implant, 13.4 ± 3.8 years; 19% Interagency Registry for Mechanically Assisted Circulatory Support [Intermacs] profile 1, 21% intubated at implant, and 12% with CHD) was significantly different from the paracorporeal continuous-flow (PC) pump cohort (n = 79; age, 3.9 ± 5.2 years; 49% Intermacs profile 1, 86% intubated at implant, and 38% with CHD) and the paracorporeal pulsatile (PP) pump cohort (n = 121; age, 3.3 ± 3.9 years; 41% Intermacs profile 1, 77% intubated at implant, and 21% with CHD). Consistent with their cohort composition, device type positive outcomes at 6 months were PC, 63%; PP, 77%; and IC, 92%. Parametric hazard modeling showed an early hazard for death was associated with Intermacs profile 1, biventricular assist device, percutaneous devices, PC devices, small-volume institutions, low age, and low weight, whereas a constant hazard was associated with intubation and liver dysfunction at time of implant.
CONCLUSIONS: IC VADs are the most common VAD type placed in children. The positive outcomes for the IC VADs exceed 90% at 6 months, which may represent our field's maturation in both patient selection and timing of implantation. The PP/PC devices are currently limited to supporting our most challenging patients, those weighing less than 20 kg and those with CHD. The introduction of new devices and our communities' commitment to shared learning and improvement will lead to more pediatric lives saved by VAD support and will also focus on improving the quality of life of children supported with VADs.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app