ENERGY RESPONSE FACTOR of BeO DOSEMETER CHIPS: A MONTE CARLO SIMULATION AND GENERAL CAVITY THEORY STUDY.

The objective of this study is to determine the energy response factors for BeO optically simulated dosemeter (OSLD) using general cavity theory and Monte Carlo (MC) simulations. A virtual phantom is constructed in EGSnrc MC program and energy response of BeO OSLDs were simulated at 5 cm depth for x-ray beams ranging from 1.25 to 25 MV and at 2 cm for beams with <250 kV including ISO 4037 narrow beam energies in a virtual water phantom. The energy response factor for a given radiation quality relative to 60Co was determined for BeO and compared to the Al2O3:C and LiF:Mg,Ti dosemeters. Burlin cavity theory calculations were done using mean photon energy (MPE) of the beam spectra, while EGSnrc software package was used to carry out MC simulation of full spectra. The cavity theory and MC methods agreed well within the 0.7%. Energy response of x-ray beams at MV range showed a maximum of 1.5% under-response. At energies higher than 150 kV (105 keV MPE) showed no significant difference while a significant under-response were observed at 100 kV (53 keV MPE) and 50 kV (29 keV MPE), ~8 and ~12%, respectively. BeO, Al2O3:C and LiF:Mg,Ti dosemeters exhibited very similar energy response at higher energies mainly in the MeV range. At 50 kV (29 keV MPE), however, BeO dosemeter under responded by a factor of 0.878, while Al2O3:C and LiF:Mg,Ti dosemeters over responded by a factor of 3.2 and 1.44, respectively. Furthermore, at low energies, BeO energy response showed dependence on photon spectra. For instance, at 100 kV, the difference was ~8, ~6 and 2% for 53, 60 and 83 keV MPE (ISO 4037N-100), respectively. Furthermore, calibration with 137Cs instead of 60Co resulted up to 1.8% differences in energy response. Both energy spectrum and calibration methods make considerable differences in energy response of OSLDs. This study concludes that BeO chips are nearly energy independent at energies higher than 100 keV MPE, while Al2O3:C dosemeters show an extremely enhanced energy-response ranging between 1.44 and 3.2 at energies between 170 and 29 keV MPE mainly due to dominance of photoelectric effect.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app