Add like
Add dislike
Add to saved papers

Novel ring artifact suppression method for CBCT imaging with two-dimensional antiscatter grids.

Medical Physics 2019 Februrary 26
PURPOSE: Two-dimensional antiscatter grids (2DASG) for cone beam computed tomography (CBCT) is a new area of research to reduce scatter intensity, and consequently improve CBCT image quality. One of the challenges in implementation of 2DASGs is their septa shadows that are impinged on the projections. If these artifacts are not corrected, they may lead to ring artifacts in CBCT images. In this work, we present a novel method to suppress ring artifacts in at panel detector based CBCT images.

METHODS: Briey, our method first detects the locations of 2DASG's septa shadows in projections and then, reduces projection pixel values in septa shadows iteratively until a residual-based convergence criterion is met. To suppress the 2DASG's septa shadows, we developed a total variation minimization (TVM) formulation, referred to as adaptive-diffusive total variation minimization (adTVM), where the diffusivity regularization parameter was adaptively adjusted during each iteration based on the magnitude of the local the pixel gradients. To test our method, we have acquired CBCT scans of phantoms using three 2DASG prototypes with different grid geometries. Projections were acquired with a linac mounted CBCT system, operated in offset detector geometry. These projections were then corrected in the following steps: first, projections were corrected using a gantry angle-specific gain correction map; next, projections were corrected by applying our adTVM method. CBCT images were reconstructed using FDK filtered backprojection algorithm. To evaluate adTVM's performance, pixel value statistics and contrast-to-noise ratio (CNR) were compared in CBCT images corrected with and without our adTVM method.

RESULTS: Without our adTVM method, all three 2DASG prototypes introduced ring artifacts with varying intensities in CBCT images. With our method, significant reduction in ring artifacts was observed in all test cases. Standard deviation of CT numbers was reduced by 7-74% in uniform density phantom CBCT images, CNR was increased by 8% to 67%, and CT number accuracy of contrast objects embedded in the phantom was preserved.

CONCLUSION: We propose a new method to suppress ring artifacts caused by 2DASGs septa shadows in CBCT images. Our initial investigations indicated that adTVM method could substantially reduce such ring artifacts while preserving CT number accuracy and maintaining good spatial resolution. Therefore, our method may potentially play an important role in enabling the implementation of 2DASGs in at panel detector based CBCT systems. This article is protected by copyright. All rights reserved.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app