We have located links that may give you full text access.
Production of RBC autoantibody mimicking anti-D specificity following transfusion in a patient with weak D Type 15.
Transfusion 2019 April
BACKGROUND: Weak D-type RBCs have fewer D epitopes, but it remains unclear whether individuals with certain types of weak D produce alloanti-D directed at D epitopes absent from the RBCs, and whether it is an alloantibody or an autoantibody. We report the first case of a patient with a weak D Type 15 who produced autoantibodies mimicking alloanti-D.
CASE REPORT: A 52-year-old Japanese male with weak D developed anti-D 3 months after transfusion of D-negative and -positive RBCs, and the antibody persisted for 24 months with a consistently negative direct antiglobulin test. Eluates from the patient's RBCs demonstrated anti-D specificity. The recipient did not exhibit any signs of delayed hemolytic transfusion reaction. As his anti-D was removed by the different adsorbing cells of weak D Type 15 and autologous as well as D positive, D negative, weak D Type 24, and partial DVa, it was thought to be an autoantibody mimicking anti-D rather than an alloantibody. The patient's RBCs reacted weakly with the 13 anti-D reagents used in the study. Polymerase chain reaction and nucleotide sequencing revealed that the patient had an RHD genotype of RHD*01N.01/RHD*15.
CONCLUSION: Anti-D, produced in a patient with weak D Type 15 after transfusion, was found to be mimicking autoanti-D. Alloanti-D was excluded by an adsorption study with different RBC types.
CASE REPORT: A 52-year-old Japanese male with weak D developed anti-D 3 months after transfusion of D-negative and -positive RBCs, and the antibody persisted for 24 months with a consistently negative direct antiglobulin test. Eluates from the patient's RBCs demonstrated anti-D specificity. The recipient did not exhibit any signs of delayed hemolytic transfusion reaction. As his anti-D was removed by the different adsorbing cells of weak D Type 15 and autologous as well as D positive, D negative, weak D Type 24, and partial DVa, it was thought to be an autoantibody mimicking anti-D rather than an alloantibody. The patient's RBCs reacted weakly with the 13 anti-D reagents used in the study. Polymerase chain reaction and nucleotide sequencing revealed that the patient had an RHD genotype of RHD*01N.01/RHD*15.
CONCLUSION: Anti-D, produced in a patient with weak D Type 15 after transfusion, was found to be mimicking autoanti-D. Alloanti-D was excluded by an adsorption study with different RBC types.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app