A cone-shaped gradient coil design for high-resolution MRI head imaging.

Insertable head gradient coils offer significant advantages such as high gradient strength and fast gradient switching speed owing to close distance to the target region of interest than whole-body cylindrical coils. To produce superior gradient performance, the local head coil is typically designed with an asymmetric configuration to accommodate both the shoulders and head of a patient, leading to tough dimensional constraints and practical limits to the coil implementation. In this paper, we proposed a new cone-shaped model to improve the performance of the asymmetric head coils and also to mitigate patient claustrophobia. The primary coils were designed with a larger diameter at the patient end for access and a smaller diameter at the service end to bring wires closer to the human head, while the secondary coils were arranged on a cylindrical former to improve coil efficiency. Two cases were studied in this paper. (1) case I: inner bore size at the patient end (diameter 42 cm) is fixed as the design reference. In this case, inner diameters at any other position vary with the conical tilting angles. Compared with a set of conical gradient coils designed with tilting angles ranging from 0 to 14 degrees, it is found that the optimal coil performance is achieved at the tilting angle of 14 degrees. The key performance parameters have been improved by 100%~200% for the transverse coils, and about 50% for the longitudinal coils compared with the cylindrical counterpart with the reference bore size (that is, the same diameter of 42 cm). The conical coils also produce less heat in the gradient structure and lower acoustic noise in the field of view. (2) case II: inner bore size at the iso-centre (diameter 34 cm) is set as the design reference. It is also found that, compared with 34 cm diameter cylindrical coils, the conical transverse coil performance has been improved at angle 14 degrees. The key coil performance increases by 20%~50% for transverse coil but decreases by 20%~40% for the longitudinal coil. However, compared with the tight cylindrical structure (e.g. 34 cm diameter), the tilting angle will provide patient-friendly space for imaging and handling, which can be critical for fMRI and other brain studies.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app