We have located links that may give you full text access.
Urea dilution of serum for reproducible anti-HSV1 IgG avidity index.
BMC Infectious Diseases 2019 Februrary 15
BACKGROUND: Herpes simplex virus type 1 (HSV1), establishes life-long latency and can cause symptoms during both first-time infection and later reactivation. The aim of the present study was to describe a protocol to generate a reliable and discriminative avidity index (AI) for anti-HSV1 IgG content in human sera.
METHODS: Human serum from two distinct cohorts; one a biobank collection (Betula) (n = 28), and one from a clinical diagnostics laboratory at Northern Sweden University Hospital (NUS) (n = 18), were assessed for presence of IgG antibodies against HSV1 by a commercially available ELISA-kit. Addition of urea at the incubation step reduces effective binding, and the ratio between urea treated sample and non-treated sample was used to express an avidity index (AI) for individual samples.
RESULTS: AI score ranged between 43.2 and 73.4% among anti-HSV1 positive biobank sera. Clinical samples ranged between 36.3 and 74.9%. Reproducibility expressed as an intraclass correlation coefficient (ICC) was estimated at 0.948 (95% CI: 0.900-0.979) and 0.989 (95% CI 0.969-0.996) in the biobank and clinical samples, respectively.
CONCLUSION: The method allows for AI scoring of anti-HSV1 IgG from individual human sera with a single measurement. The least significant change between two measurements at the p < 0.05 level was estimated at 5.4 and 3.2 points, respectively, for the two assessed cohorts.
METHODS: Human serum from two distinct cohorts; one a biobank collection (Betula) (n = 28), and one from a clinical diagnostics laboratory at Northern Sweden University Hospital (NUS) (n = 18), were assessed for presence of IgG antibodies against HSV1 by a commercially available ELISA-kit. Addition of urea at the incubation step reduces effective binding, and the ratio between urea treated sample and non-treated sample was used to express an avidity index (AI) for individual samples.
RESULTS: AI score ranged between 43.2 and 73.4% among anti-HSV1 positive biobank sera. Clinical samples ranged between 36.3 and 74.9%. Reproducibility expressed as an intraclass correlation coefficient (ICC) was estimated at 0.948 (95% CI: 0.900-0.979) and 0.989 (95% CI 0.969-0.996) in the biobank and clinical samples, respectively.
CONCLUSION: The method allows for AI scoring of anti-HSV1 IgG from individual human sera with a single measurement. The least significant change between two measurements at the p < 0.05 level was estimated at 5.4 and 3.2 points, respectively, for the two assessed cohorts.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app