SVD-based Separation of Stable and Inertial Cavitation Signals Applied to Passive Cavitation Mapping During HIFU.
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control 2019 Februrary 14
Detection of inertial and stable cavitation is important for guiding high-intensity focused ultrasound (HIFU). Acoustic transducers can passively detect broadband noise from inertial cavitation and the scattering of HIFU harmonics from stable cavitation bubbles. Conventional approaches to cavitation noise diagnostics typically involve computing the Fourier transform of the time domain noise signal, applying a custom comb-filter to isolate the frequency components of interest, followed by an Inverse-Fourier transform. We present an alternative technique based on singular value decomposition (SVD) that efficiently separates the broadband emissions and HIFU harmonics. Spatio-temporally resolved cavitation detection was achieved using a 128-element, 5-MHz linear-array ultrasound imaging system operating in receive mode at 15 frames/s. A 1.1-MHz transducer delivered HIFU to tissue-mimicking phantoms and excised liver tissue for a duration of 5 s. Beamformed radiofrequency signals corresponding to each scan line in a frame were assembled into a matrix and SVD was performed. Spectra of the singular-vectors obtained from a tissue-mimicking gel phantom were analyzed by computing the peak ratio (R), defined as the ratio of the peak of its 5th-order polynomial fit and the maximum spectral peak. Singular-vectors that produced a R<0.048 were classified as those representing stable cavitation, i.e., predominantly containing harmonics of HIFU. The projection of data onto this singular-base reproduced stable-cavitation signals. Similarly, singular-vectors that produced a R>0.2 were classified as those predominantly containing broadband noise associated with inertial cavitation. These singular-vectors were used to isolate the inertial-cavitation signal. The R-value thresholds determined using gel data were then employed to analyze cavitation data obtained from bovine liver ex vivo. The SVD-based method faithfully reproduced the structural details in the spatio-temporal cavitation maps produced using the more cumbersome comb-filter approach with a maximum root-mean-squared error of 10%.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app