We have located links that may give you full text access.
Serum endocan level and diastolic functions in the case of lead exposure
Turkish Journal of Medical Sciences 2019 Februrary 12
Background/aim: Lead can cause morphological and functional changes in heart, and inflammation and endothelial dysfunction in vasculature. Endocan, as a novel indicator of endothelial dysfunction, has been used for cardiovascular diseases. This study investigated the relationship between lead exposure, endocan levels, and diastolic functions.
Materials and methods: A total of 51 lead-exposed workers without a known cardiovascular disease or risk factors and 54 healthy controls were enrolled. All participants underwent transthoracic echocardiography. Blood lead and serum endocan levels were analyzed.
Results: Baseline demographic and clinical characteristics were found to be similar between groups. Median blood lead (32 vs 1.5 μg/dL, P < 0.001) and serum endocan levels (67 vs 57.1 pg/mL, P = 0.02) were significantly higher in the lead-exposed group. Serum endocan level showed a positive correlation with blood lead levels (r = 0.404, P = 0.003) in lead-exposed workers. Serum endocan level was an independent risk factor for increased E/E’ ratio (β = 0.704, P = 0.002) and left atrial volume index (β = 1.158, P = 0.011) and higher level of lead in blood was an independent risk factor for increased E wave (β = 8.004, P = 0.022) in lead-exposed workers.
Conclusion: Worsened diastolic functions may be seen in the course of lead exposure. Due to sharing a similar mechanism, a higher serum level of endocan may be a valuable laboratory clue for impaired diastolic function in this population.
Materials and methods: A total of 51 lead-exposed workers without a known cardiovascular disease or risk factors and 54 healthy controls were enrolled. All participants underwent transthoracic echocardiography. Blood lead and serum endocan levels were analyzed.
Results: Baseline demographic and clinical characteristics were found to be similar between groups. Median blood lead (32 vs 1.5 μg/dL, P < 0.001) and serum endocan levels (67 vs 57.1 pg/mL, P = 0.02) were significantly higher in the lead-exposed group. Serum endocan level showed a positive correlation with blood lead levels (r = 0.404, P = 0.003) in lead-exposed workers. Serum endocan level was an independent risk factor for increased E/E’ ratio (β = 0.704, P = 0.002) and left atrial volume index (β = 1.158, P = 0.011) and higher level of lead in blood was an independent risk factor for increased E wave (β = 8.004, P = 0.022) in lead-exposed workers.
Conclusion: Worsened diastolic functions may be seen in the course of lead exposure. Due to sharing a similar mechanism, a higher serum level of endocan may be a valuable laboratory clue for impaired diastolic function in this population.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app